arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1902.08665eess.SPphysics.ins-det
收藏

应用反卷积恢复频域复用探测器脉冲

Application of deconvolution to recover frequency-domain multiplexed detector pulses

M. Mishra, J. Mattingly, R. M. Kolbas

摘要:

辐射探测器的多路复用减少了读出通道的数量,这又减少了用于数据采集的数字化仪输入通道的数量。我们最近演示了脉冲模式辐射探测器的频域复用(FDM),使用谐振器将探测器信号通过卷积转换为阻尼正弦曲线。每个谐振器的振荡频率为探测器赋予了独特的“标签”。从频域中相应的谐振器输出估计收集的电荷和检测器脉冲的到达时间。在本文中,我们提出了一种新的方法来恢复检测器脉冲从阻尼正弦输出的反卷积。反卷积将频率编码的检测器信号转换回原始检测器脉冲。我们已经开发了一个新的原型FDM系统的基础上卷积和去卷积的多个有机溶剂。使用新的原型,阳极脉冲下收集的电荷可以估计从恢复的脉冲与约4.4 keV(keV电子当量)的不确定性。可以从恢复的脉冲估计到达时间,具有约102 ps的不确定性。我们还使用CeBr 3无机闪烁体使用恢复的脉冲测量Cs-137伽马光谱,发现662 keV处的标准偏差为13.8 keV,而使用原始脉冲时的标准偏差为13.5 keV。与使用原始脉冲的603 ps的不确定性相比,使用去卷积脉冲的Na-22的符合测量导致617 ps的定时不确定性。脉冲形状的歧视,也进行了使用Cf-252源和EJ-309有机闪烁体脉冲恢复反卷积。与原始脉冲的1.2相比,当使用恢复的脉冲时观察到的品质因数值为1.08。

英文摘要:

Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detectors using a resonator that converts the detector signal into a damped sinusoid by convolution. The detectors were given unique "tags" by the oscillation frequency of each resonator. The charge collected and the time-of-arrival of the detector pulse were estimated from the corresponding resonator output in the frequency domain. In this paper, we demonstrate a new method to recover the detector pulse from the damped sinusoidal output by deconvolution. Deconvolution converts the frequency-encoded detector signal back to the original detector pulse. We have developed a new prototype FDM system to multiplex organic scintillators based on convolution and deconvolution. Using the new prototype, the charge collected under the anode pulse can be estimated from the recovered pulse with an uncertainty of about 4.4 keVee (keV electron equivalent). The time-of-arrival can be estimated from the recovered pulse with an uncertainty of about 102 ps. We also used a CeBr3 inorganic scintillator to measure the Cs-137 gamma spectrum using the recovered pulses and found a standard deviation of 13.8 keV at 662 keV compared to a standard deviation of 13.5 keV when the original pulses were used. Coincidence measurements with Na-22 using the deconvolved pulses resulted in a timing uncertainty of 617 ps compared to an uncertainty of 603 ps using the original pulses. Pulse shape discrimination was also performed using Cf-252 source and EJ-309 organic scintillator pulses recovered by deconvolution. A figure of merit value of 1.08 was observed when the recovered pulses were used compared to 1.2 for the original pulses.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑