Non-destructive and reliable quality control methods are a key aspect to designing, developing and manufacturing new materials for industrial applications and new technologies. The measurement of the magnetic saturation is one of such methods and it is conventionally employed in the cemented carbides industry. We present a general quantum mechanics based relation between the magnetic saturation and the components of the binder phase of cemented carbides, which can be directly employed as a quality control. To illustrate our results, we calculate the magnetic saturation of a binder phase, 85Ni15Fe binary alloy, using ab-initio methods and compare the theoretical predictions to the magnetic saturation measurements. We also analyse interface and segregation effects on the magnetic saturation by studying the electronic structure of the binder phase. The excellent agreement between calculations and measurements demonstrates the applicability of our method to any binder phase. Since the magnetic saturation is employed to ensure the quality of cemented carbides, the present method allows us to explore new materials for alternative binder phases efficiently
Mechanical properties of B12-based orthorhombic metal carboborides. A first principle study
Shanghai Institute of Ceramics, Chinese Academy of Sciences(中国科学院上海陶瓷研究所);University of Chinese Academy of Sciences(中国科学院大学);Frantsevich Institute for Problems of Materials Science, National Academy of Science of Ukraine(乌克兰国家科学院弗兰采维奇材料科学问题研究所)
Accelerated Design of Mechanically Hard Magnetically Soft High-entropy Alloys via Multi-objective Bayesian Optimization
Institute of Materials Science, Technical University of Darmstadt(达姆施塔特工业大学材料科学研究所);Department of Materials Science and Engineering, KTH - Royal Institute of Technology(皇家理工学院材料科学与工程系);Max Planck Institute for Sustainable Materials(马克斯·普朗克可持续材料研究所);College of Carbon Neutrality Future Technology, China University of Petroleum(中国石油大学碳中和未来技术学院)
Ti$_{1-x}$Au$_x$ Alloys: Hard Biocompatible Metals and Their Possible Applications
从理论和实验的角度来看,寻找新的硬质材料往往具有挑战性。此外,将材料用于生物医学应用需要具有高生物相容性的合金,其甚至更稀疏。Ti $_{1-x}$ Au $_x$($0.22 \leq x \leq 0.8$)具有极高的硬度和强度值、较高的熔化温度(与组成元素相比)、较低的密度(与Au相比)、较高的延展性、大量金属性、较高的生物相容性、较低的磨损、较低的摩擦、潜在的较高的射线不透性以及骨整合。所有这些特性使得Ti $_{1-x}$ Au $_x$合金特别适用于骨科、牙科和假体应用,在这些应用中,它们可用作永久性和临时性组件。此外,Ti $_{1-x}$ Au $_x$合金粘附到陶瓷部件上的能力可以降低这些部件的重量和成本。
Insulator-to-metal transition in the pyrochlore iridates series (Eu_1-xBi_x)2Ir2O7 probed using Hard X-ray Photoemission Spectroscopy
Eu 2 Ir 2 O 7,一个候选的Weyl半金属,显示了绝缘体到金属的过渡作为Bi取代在Eu网站的功能。本文采用硬X射线光电子能谱(HAXPES)研究了(Eu_(1-x)Bi_x)_2 Ir_2 O_7系列样品,发现Bi ~(3+)掺杂Eu ~(3+)时,在低Bi掺杂(3.5%)时,出现了20%的晶格收缩.使用HAXPES,我们确认,所有的阳离子保持其名义价态在整个系列。Bi芯能级谱的非对称性质的组合物中的金属区域表明,Bi有助于在此掺杂范围内的费米能的状态密度。价带谱表明Bi 6s峰在整个系列中没有改变,并且位于价带内的深处。基于这些观察,我们认为Bi 6p-Ir 5d杂化驱动绝缘体到金属的转变。