使用不同异构数据库的自动EEG唤醒检测算法的大规模验证

Large-scale validation of an automatic EEG arousal detection algorithm using different heterogeneous databases

Diego Alvarez-Estevez, Isaac Fernández-Varela

摘要:

$\textbf{Objective}$:为了评估使用大患者样本和不同异构数据库$\textbf{Methods}$的自动EEG觉醒检测算法的有效性:将自动评分结果与从两个不同数据库获得的总计2768个整夜PSG记录的人类专家评分结果进行比较。其中,472个记录是在我们的睡眠中心的临床常规期间获得的,并被细分为两个亚组,每个亚组220个(HMC-S)和252个(HMC-M)记录,在视觉审查期间由临床专家遵循程序(分别为半自动或纯手动)。此外,对来自公共SHHS-2数据库的2296个记录进行了评价,以对照各自的手动专家评分。$\textbf{Results}$:基于事件的逐事件阶段验证得出的总体Cohen kappa一致性K = 0.600(HMC-S)、0.559(HMC-M)和0.573(SHHS-2)。数据集上的估计评分员间变异性分别为K = 0.594、0.561和0.543。对相应的唤醒指数评分的分析显示,相关的自动-人类重复性指数范围为0.693-0.771(HMC-S)、0.646-0.791(HMC-M)和0.759-0.791(SHHS-2)。$\textbf{Conclusions}$:我们的自动EEG觉醒检测器在不同数据库上的大规模验证显示出与人类协议的预期水平相当的鲁棒性能和良好的泛化结果。特别强调的是允许结果的可重复性,并且我们的方法的实施已经作为开源代码在线访问

英文摘要:

$\textbf{Objective}$: To assess the validity of an automatic EEG arousal detection algorithm using large patient samples and different heterogeneous databases $\textbf{Methods}$: Automatic scorings were confronted with results from human expert scorers on a total of 2768 full-night PSG recordings obtained from two different databases. Of them, 472 recordings were obtained during clinical routine at our sleep center and were subdivided into two subgroups of 220 (HMC-S) and 252 (HMC-M) recordings each, attending to the procedure followed by the clinical expert during the visual review (semi-automatic or purely manual, respectively). In addition, 2296 recordings from the public SHHS-2 database were evaluated against the respective manual expert scorings. $\textbf{Results}$: Event-by-event epoch-based validation resulted in an overall Cohen kappa agreement K = 0.600 (HMC-S), 0.559 (HMC-M), and 0.573 (SHHS-2). Estimated inter-scorer variability on the datasets was, respectively, K = 0.594, 0.561 and 0.543. Analyses of the corresponding Arousal Index scores showed associated automatic-human repeatability indices ranging in 0.693-0.771 (HMC-S), 0.646-0.791 (HMC-M), and 0.759-0.791 (SHHS-2). $\textbf{Conclusions}$: Large-scale validation of our automatic EEG arousal detector on different databases has shown robust performance and good generalization results comparable to the expected levels of human agreement. Special emphasis has been put on allowing reproducibility of the results and implementation of our method has been made accessible online as open source code

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑