时间分辨荧光显微术中寿命估计的Cramér-Rao分析
Cramér-Rao analysis of lifetime estimations in time-resolved fluorescence microscopy
摘要:
通过时间相关单光子计数(TCSPC)测量荧光发射体的寿命是从纳米光子学到生物学的许多研究领域中的常规程序。这种测量的精度取决于探测到的光子的数量,但也取决于测量过程中产生的各种噪声源。利用Fisher信息理论,我们计算了单指数和双指数分布下寿命估计精度的下界。我们分析了寿命估计精度对实验相关参数的依赖性,包括非均匀背景噪声和仪器响应函数(IRF)的设置的贡献。我们还提供了一个开源代码,以确定任何实验条件下的估计精度的下限。两个实际的例子说明了如何使用这个工具,以达到最佳精度的时间分辨荧光显微镜。
英文摘要:
Measuring the lifetime of fluorescent emitters by time-correlated single photon counting (TCSPC) is a routine procedure in many research areas spanning from nanophotonics to biology. The precision of such measurement depends on the number of detected photons but also on the various sources of noise arising from the measurement process. Using Fisher information theory, we calculate the lower bound on the precision of lifetime estimations for mono-exponential and bi-exponential distributions. We analyse the dependence of the lifetime estimation precision on experimentally relevant parameters, including the contribution of a non-uniform background noise and the instrument response funtion (IRF) of the setup. We also provide an open-source code to determine the lower bound on the estimation precision for any experimental conditions. Two practical examples illustrate how this tool can be used to reach optimal precision in time-resolved fluorescence microscopy.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。