arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1808.06539astro-ph.SR
收藏

用快速太阳偏振计探测Sr I $4607.3$晶体的空间结构散射偏振

Detection of spatially structured scattering polarization of Sr I $4607.3$ Å\ with the Fast Solar Polarimeter

F. Zeuner, A. Feller, F. A. Iglesias, S. K. Solanki

摘要:

高分辨率观测到的Sr I 4607.3射电望远镜中的散射极化是小空间尺度下太阳大气和磁性的重要诊断。目前,这种诊断的空间分辨观察是罕见的,并且没有像$μ=0.6$那样靠近椎间盘中心的报道。我们的目的是测量在$μ=0.6$的Sr I线的散射偏振,并确定与统计方法的空间波动。使用快速太阳偏振计(FSP)安装在TESOS滤波器在德国真空塔望远镜(VTT)在西班牙特内里费岛,我们测量了空间分辨全斯托克斯参数的Sr I线在$μ=0.6$和中心到肢体的空间平均斯托克斯参数的变化。我们发现,中心到肢体的变化与FSP测量的Sr I线的散射偏振与以前的测量是一致的。Stokes $Q/I$的统计分析(即,平行于太阳边缘的线偏振分量),在Sr I的线芯中用$0.16$ "像素$^{-1}$采样,揭示了信号强度与连续谱中的强度负相关。我们发现更强的线性极化信号对应于斯托克斯$I$连续图像中的暗区(粒间通道)。相反,在$μ=0.3$的独立测量显示出$Q/I$相对于连续强度的正相关性。我们估计导致过量$Q/I$信号的斑块直径为$0.5$ "-$1$"的量级。在$μ=0.6$上对$Q$/$I$信号进行的观测和统计分析补充了所报道的散射偏振观测和模拟。

英文摘要:

Scattering polarization in the Sr I 4607.3 Å\ line observed with high resolution is an important diagnostic of the Sun's atmosphere and magnetism at small spatial scales. At present, spatially resolved observations of this diagnostic are rare and have not been reported as close to the disk center as for $μ=0.6$. Our aim is to measure the scattering polarization in the Sr I line at $μ=0.6$ and to identify the spatial fluctuations with a statistical approach. Using the Fast Solar Polarimeter (FSP) mounted on the TESOS filtergraph at the German Vacuum Tower Telescope (VTT) in Tenerife, Spain, we measured both the spatially resolved full Stokes parameters of the Sr I line at $μ=0.6$ and the center-to-limb variation of the spatially averaged Stokes parameters. We find that the center-to-limb variation of the scattering polarization in the Sr I line measured with FSP is consistent with previous measurements. A statistical analysis of Stokes $Q/I$ (i.e., the linear polarization component parallel to the solar limb), sampled with $0.16$" pixel$^{-1}$ in the line core of Sr I reveals that the signal strength is inversely correlated with the intensity in the continuum. We find stronger linear polarimetric signals corresponding to dark areas (intergranular lanes) in the Stokes $I$ continuum image. In contrast, independent measurements at $μ=0.3$ show a positive correlation of $Q/I$ with respect to the continuum intensity. We estimate that the patch diameter responsible for the excess $Q/I$ signal is on the order of $0.5$"-$1$". The presented observations and the statistical analysis of $Q$/$I$ signals at $μ=0.6$ complement reported scattering polarization observations as well as simulations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑