AI总结:

本文提出一种基于表达gloeorhodopsin的大肠杆菌的微尺度光-化学信号转换接口,建立参数模型并设计信道估计与检测方案,实现1比特/分钟的分子通信。

摘要:

尽管分子通信(MC)系统的许多令人振奋的应用被设想处于微尺度,但迄今报道的MC测试平台大多处于宏尺度。为连接宏观世界与微观世界,我们提出并演示了一种生物信号转换接口,该接口也可视为一个微尺度调制器。具体而言,所提出的接口通过改变环境的pH值,将由LED控制的光信号转换为化学信号。该调制器利用大肠杆菌细菌作为微尺度实体来实现,这些细菌表达来自Gloeobacter violaceus的光驱动质子泵gloeorhodopsin。在受到外部光刺激时,这些细菌通过向环境中输出质子,局部改变其周围的pH水平。为验证所提出的光-化学信号转换器的有效性,我们分析了由充当接收器的pH传感器测得的pH信号。我们针对感应化学信号作为所施加光信号的函数,建立了一个解析参数模型。利用该模型,我们推导了一种基于训练的信道估计器,该估计器估计所提出模型的参数以拟合测量数据。我们进一步推导了最优最大似然检测器和次优低复杂度检测器,以从测得的接收信号中恢复传输数据。结果表明,所提出的参数模型与测量数据高度吻合。此外,在一个示例场景中,我们证明所提出的装置能够成功地将表示二进制符号序列的光信号转换为化学信号,比特率为1比特/分钟,并利用所提出的估计和检测方案从化学信号中恢复传输数据。所提出的调制器可为未来微尺度MC测试平台和应用奠定基础。

英文摘要:

Although many exciting applications of molecular communication (MC) systems are envisioned to be at microscale, the MC testbeds reported so far are mostly at macroscale. To link the macroworld to the microworld, we propose and demonstrate a biological signal conversion interface that can also be seen as a microscale modulator. In particular, the proposed interface transduces an optical signal, which is controlled using an LED, into a chemical signal by changing the pH of the environment. The modulator is realized using E. coli bacteria as microscale entity expressing the light-driven proton pump gloeorhodopsin from Gloeobacter violaceus. Upon inducing external light stimuli, these bacteria locally change their surrounding pH level by exporting protons into the environment. To verify the effectiveness of the proposed optical-to-chemical signal converter, we analyze the pH signal measured by a pH sensor, which serves as receiver. We develop an analytical parametric model for the induced chemical signal as a function of the applied optical signal. Using this model, we derive a training-based channel estimator which estimates the parameters of the proposed model to fit the measurement data. We further derive the optimal maximum likelihood detector and a suboptimal low-complexity detector to recover the transmitted data from the measured received signal. It is shown that the proposed parametric model is in good agreement with the measurement data. Moreover, for an example scenario, we show that the proposed setup is able to successfully convert an optical signal representing a sequence of binary symbols into a chemical signal with a bit rate of 1 bit/minute and recover the transmitted data from the chemical signal using the proposed estimation and detection~schemes. The proposed modulator may form the basis for future MC testbeds and applications at microscale.