arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1807.10880astro-ph.IM
收藏

基于SLS的精密photometry红外探测器的实验室表征

Laboratory characterization of SLS-based infrared detectors for precision photometry

Aaron Peterson-Greenberg, Michael D. Pavel

摘要:

应变层超晶格(SLS)探测器是一种新型的红外探测器,可用于科学和商业市场。光敏带通由材料和工程特性设置,典型的探测器覆盖7.5- 10.5微米,比传统的N波段滤波器更蓝。SLS探测器有可能达到比传统红外材料(如HgCdTe)更低的暗电流,从而在更高的探测器温度下实现相当的光度灵敏度,从而减轻冷却要求。相反,在相同的低温下,SLS探测器将具有比HgCdTe更低的暗电流,从而在暗电流受限的操作下具有更好的光度灵敏度。这项工作提出了实验室测量SLS探测器,以量化检测器的线性和时间稳定性。讨论了SLS探测器在未来天文仪器中的潜在优势.

英文摘要:

Strained layer superlattice (SLS) detectors are a new class of infrared detectors available in the scientific and commercial markets. The photosensitive bandpass is set by material and engineered properties with typical detectors covering 7.5- 10.5 microns, bluer than traditional N-band filters. SLS detectors have the potential to reach lower dark current than traditional infrared materials (like HgCdTe) allowing comparable photometric sensitivity at higher detector temperatures, easing cooling requirements. Conversely, at equal cryogenic temperatures the SLS detector will have lower dark current than HgCdTe allowing better photometric sensitivity under dark current limited operation. This work presents laboratory measurements of SLS detectors to quantify detector linearity and time stability. The potential advantages in using SLS- based detectors in future astronomical instruments is also discussed.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑