一个简单的装置,用于显微注射,操作和测量,使用电形态芯片,在不同角度下,在5-1000 nm厚度范围内,在界面和膜过程的显微干涉控制下,

A simple device for microinjections, manipulations and measurements using an electromorphological chip under microinterferometric control of the interface and membrane processes at the thickness range of 5-1000 nm at different angles

O. V. Gradov, P. A. Nasirov, A. A. Scrynnic, A. G. Jablokov

摘要:

使用填充有电解质的玻璃微电极进行的显微操作、灌注和测量是在单细胞和膜表面水平进行实验形态学和膜电生理学研究的常规技术。玻璃微电极端部的典型(有效)直径为500至小于100 nm,这阻止了根据光学分辨率标准使用标准光学显微镜观察它,因为小于500 nm的直径在干涉区内是不可区分的。提供拉动和撕裂的拉动器(microforge)的微处理器编程允许在某些方案中获得微量移液管尖端的经调节的直径和形状,尽管由于上述限制,该结果不完全受控。在这方面,有必要在准备和操作阶段(细胞内或细胞外插入)设计用于微量移液管尖端的控制装置。该方法还应根据电极类型和状态实时提供微电极尖端与细胞相互作用时发生的过程的可视化,这允许在用电解质填充微电极的不同方式之后使由微量移液管尖端的不受控制的操作引起的系统误差频率引起的伪影水平化。我们提出了一种安装方案,解决了上述问题,通过引入一个干涉仪装置的显微控制的微电极和显微操作器或微灌注,第一次为一个给定类型的光学仪器相结合的干涉光学方案。

英文摘要:

Micromanipulations, perfusions and measurements performed using glass microelectrodes filled with an electrolyte is a conventional technique for experimental morphological and membrane electrophysiological studies at a single cell and membrane surface level. The typical (effective) diameter of the end of the glass microelectrode is from 500 up to less than 100 nm, which prevents one from observing it using a standard optical microscope in accordance with the optical resolution criteria, since the diameter less than 500 nm is indistinguishable within the interference zone. Microprocessor programming of the puller (microforge) that provides pulling and tearing allows to obtain in certain regimes the adjusted diameter and shape of the micropipette tip, although this result is not fully controlled due to the above limitations. In this connection it is necessary to design the control devices for the micropipette tips both at the preparation and operation stages (intracellular or extracellular insertion). This method also should provide visualization of the processes occurring upon interaction of the microelectrode tip with the cell in real time, depending on the electrode type and state, which allows to level the artifacts arising with the systematic error frequency from the uncontrolled operation of the micropipette tip after different ways of the microelectrode filling with the electrolyte. We propose an installation scheme that solves the above problems by means of introducing an interferometric device for microscopic control of the microelectrode and micromanipulator or microperfusor, for the first time for a given type of optical instruments combined with the interferometric optical scheme.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑