arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1807.02435physics.ins-det
收藏

隔离自由落体试验质量的精确电荷控制:LISA Pathfinder结果

Precision Charge Control for Isolated Free-Falling Test Masses: LISA Pathfinder Results

M. Armano, H. Audley, J. Baird, P. Binetruy, M. Born, D. Bortoluzzi, E. Castelli, A. Cavalleri, A. Cesarini, A. M. Cruise, K. Danzmann, M. de Deus Silva, I. Die… 展开作者

M. Armano, H. Audley, J. Baird, P. Binetruy, M. Born, D. Bortoluzzi, E. Castelli, A. Cavalleri, A. Cesarini, A. M. Cruise, K. Danzmann, M. de Deus Silva, I. Diepholz, G. Dixon, R. Dolesi, L. Ferraioli, V. Ferroni, E. D. Fitzsimons, M. Freschi, L. Gesa, D. Giardini, F. Gibert, R. Giusteri, C. Grimani, J. Grzymisch, I. Harrison, G. Heinzel, M. Hewitson, D. Hollington, D. Hoyland, M. Hueller, H. Inchauspé, O. Jennrich, P. Jetzer, N. Karnesis, B. Kaune, N. Korsakova, C. J. Killow, L. Liu, I. Lloro, J. A. Lobo, J. P. López-Zaragoza, R. Maarschalkerweerd, F. Mailland, D. Mance, V. Martín, L. Martin-Polo, F. Martin-Porqueras, J. Martino, I. Mateos, P. W. McNamara, J. Mendes, L. Mendes, N. Meshskar, M. Nofrarias, S. Paczkowski, M. Perreur-Lloyd, A. Petiteau, M. Pfeil, P. Pivato, E. Plagnol, J. Ramos-Castro, J. Reiche, D. I. Robertson, F. Rivas, G. Russano, G. Santoruvo, P. Sarra, D. Shaul, J. Slutsky, C. F. Sopuerta, T. Sumner, D. Texier, J. I. Thorpe, C. Trenkel, D. Vetrugno, S. Vitale, G. Wanner, H. Ward, S. Waschke, P. J. Wass, W. J. Weber, L. Wissel, A. Wittchen, P. Zweifel

摘要:

LISA探路者电荷管理装置负责中和宇宙射线感应的电荷,这些电荷不可避免地积累在实验核心的自由落体测试质量上。我们提出了在地面和飞行中进行的测量,量化了这种非接触式放电系统的性能,该系统是基于紫外光照射下的光发射。此外,一个两部分的模拟描述了一起开发的硬件。用GEANT 4软件工具包对Pathfinder传感器内吸收的UV光进行建模,并且单独的MATLAB电荷转移模型计算在存在AC和DC电场的情况下测试质量与周围外壳之间的净光电流。我们面对这些模型的结果与观察,并得出结论,放电系统的设计,为未来的实验,如LISA,也将采用自由落体测试群众。

英文摘要:

The LISA Pathfinder charge management device was responsible for neutralising the cosmic ray induced electric charge that inevitably accumulated on the free-falling test masses at the heart of the experiment. We present measurements made on ground and in-flight that quantify the performance of this contactless discharge system which was based on photo-emission under UV illumination. In addition, a two-part simulation is described that was developed alongside the hardware. Modelling of the absorbed UV light within the Pathfinder sensor was carried out with the GEANT4 software toolkit and a separate MATLAB charge transfer model calculated the net photocurrent between the test masses and surrounding housing in the presence of AC and DC electric fields. We confront the results of these models with observations and draw conclusions for the design of discharge systems for future experiments like LISA that will also employ free-falling test masses.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑