使用PROBA-3/ASPIICS日冕仪上的D3线路滤波器的日珥可见性
Visibility of Prominences using the HeI D3 Line Filter on PROBA-3/ASPIICS Coronagraph
摘要:
我们确定了一个最佳的宽度和形状的窄带过滤器围绕He\,{ \sc i} D $_{3}$线的日珥和日冕物质抛射(CME)的观测与ASPIICS({ \it日冕偏振和成像研究航天器协会})PROBA-3上的日冕仪({ \it Project for On-board Autonomy})卫星,将于2020年发射。利用辐射传输程序计算了温度为8,30和100 kK时三种典型的非LTE日珥模型的He,{ \sc i} D $_{3}$谱线强度,并分析了日珥电子汤姆逊散射引起的可见光发射.我们计算了日珥视线速度为0、100和300 km s $^{-1}$时,20 μ m宽的平坦滤波器和半高宽分别为5、10和20 μ m的高斯滤波器的各种有用关系,以显示氦的相对亮度贡献,{ \sc i} D $_{3}$线和突出VL与给定窄带滤光片中的可见度的关系。我们还讨论了可能的信号污染Na,{ \sc i} D $_{1}$和D $_{2}$线,否则可能是有用的检测彗星。结果主要显示:i)为了检测快速移动的日珥结构,最佳窄带滤波器应该是平坦的或介于平坦和高斯之间的某个地方,具有20 kK的FWHM,ii)He I,{ \sc i} D $_3$线中的最大发射在30 kK处,最小在100 kK处,以及iii)He I,{\sc i} D中的发射比,{ \sc i} D $_3$谱线对VL辐射的响应可以提供日珥结构温度的有用诊断。这个比率在热日珥结构中高达10,在冷结构中高达100,在暖结构中高达1000。
英文摘要:
We determine an optimal width and shape of the narrow-band filter centered around the He\,{\sc i} D$_{3}$ line for prominence and coronal mass ejection (CME) observations with the ASPIICS ({\it Association of Spacecraft for Polarimetric and Imaging Investigation of the Corona of the Sun}) coronagraph onboard the PROBA-3 ({\it Project for On-board Autonomy}) satellite, to be launched in 2020. We analyze He\,{\sc i} D$_{3}$ line intensities for three representative non-LTE prominence models at temperatures 8, 30 and 100~kK computed by the radiative transfer code and the prominence visible-light (VL) emission due to Thomson scattering on the prominence electrons. We compute various useful relations at prominence line-of-sight (LOS) velocities of 0, 100, and 300~km~s$^{-1}$ for 20~Å~wide flat filter and three Gaussian filters with full width at half maximum (FWHM) equal to 5, 10, and 20~Å~to show the relative brightness contribution of the He\,{\sc i} D$_{3}$ line and the prominence VL to the visibility in a given narrow-band filter. We also discuss possible signal contamination by Na\,{\sc i} D$_{1}$ and D$_{2}$ lines which otherwise may be useful to detect comets. Results mainly show: i) an optimal narrow-band filter should be flat or somewhere between flat and Gaussian with FWHM of 20~Å~in order to detect fast moving prominence structures, ii) the maximum emission in the He\,{\sc i} D$_3$ line is at 30~kK and the minimal at 100~kK, and iii) the ratio of emission in the He\,{\sc i} D$_3$ line to the VL emission can provide a useful diagnostic for the temperature of prominence structures. This ratio is up to 10 for hot prominence structures, up to 100 for cool structures and up to 1000 for warm structures.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。