arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1806.05569cs.CV
收藏

采用分段和受试者水平非局部建模的心脏运动评分

Cardiac Motion Scoring with Segment- and Subject-level Non-Local Modeling

Western University(韦仕敦大学);Shenzhen University(深圳大学)

Wufeng Xue, Gary Brahm, Stephanie Leung, Ogla Shmuilovich, Shuo Li

摘要:

心肌运动评分对于各种心脏疾病的早期检测和诊断至关重要。它旨在将局部室壁运动识别为四种类型之一,包括正常、运动减退、运动不能和运动障碍,并且由于复杂的心肌变形和运动模式的细微类间差异而极具挑战性。所有现有的自动运动分析的工作都集中在二进制异常检测,以避免更苛刻的运动评分,这是迫切需要在实际的临床实践中,但从来没有被调查过。在这项工作中,我们提出了Cardiac-MOS,这是第一个基于深度卷积神经网络的心脏MR序列心脏运动评分的强大方法。由于卷积的局部性,不能探索特征图的远距离非局部响应之间的关系,这与段之间的运动差异密切相关。在Cardiac-MOS中,这种非局部关系是用一个受试者的每个分段内和所有分段上的非局部神经网络建模的,即,分段和主题级非局部建模,并导致明显的性能改善。此外,Cardiac-MOS算法通过沿时间维插值卷积核,可以有效地从不同长度的MR序列中提取运动信息,因此可以应用于多源MR序列。对90例受试者1440个不同长度短轴MR序列心肌节段的实验表明,Cardiac-MOS算法性能可靠,运动评分指数估计相关系数为0.926,运动评分准确率为77.4%。Cardiac-MOS在二进制异常检测方面也优于所有现有的工作。作为第一个自动运动评分解决方案,Cardiac-MOS在未来的临床应用中表现出巨大的潜力。

英文摘要:

Motion scoring of cardiac myocardium is of paramount importance for early detection and diagnosis of various cardiac disease. It aims at identifying regional wall motions into one of the four types including normal, hypokinetic, akinetic, and dyskinetic, and is extremely challenging due to the complex myocardium deformation and subtle inter-class difference of motion patterns. All existing work on automated motion analysis are focused on binary abnormality detection to avoid the much more demanding motion scoring, which is urgently required in real clinical practice yet has never been investigated before. In this work, we propose Cardiac-MOS, the first powerful method for cardiac motion scoring from cardiac MR sequences based on deep convolution neural network. Due to the locality of convolution, the relationship between distant non-local responses of the feature map cannot be explored, which is closely related to motion difference between segments. In Cardiac-MOS, such non-local relationship is modeled with non-local neural network within each segment and across all segments of one subject, i.e., segment- and subject-level non-local modeling, and lead to obvious performance improvement. Besides, Cardiac-MOS can effectively extract motion information from MR sequences of various lengths by interpolating the convolution kernel along the temporal dimension, therefore can be applied to MR sequences of multiple sources. Experiments on 1440 myocardium segments of 90 subjects from short axis MR sequences of multiple lengths prove that Cardiac-MOS achieves reliable performance, with correlation of 0.926 for motion score index estimation and accuracy of 77.4\% for motion scoring. Cardiac-MOS also outperforms all existing work for binary abnormality detection. As the first automatic motion scoring solution, Cardiac-MOS demonstrates great potential in future clinical application.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑