准静电人体通信的BioPhysical建模、表征与优化

BioPhysical Modeling, Characterization and Optimization of Electro-Quasistatic Human Body Communication

Shovan Maity, Mingxuan He, Mayukh Nath, Debayan Das, Baibhab Chatterjee, Shreyas Sen

摘要:

人体通信(Human Body Communication,HBC)已经成为无线电波通信的替代方案,用于连接人体内、人体上和人体周围的低功率、小型化可穿戴和可植入设备,其使用人体作为通信信道。先前表征人体通道的研究已经报道了广泛变化的通道响应,其中大部分归因于测量设置的变化。这就要求建立一个统一的HBC生物物理模型,并对HBC测量结果进行深入分析和理解。本文描述了高达1MHz频率的人体信道,以评估其作为宽带通信的介质。HBC的集总生物物理模型的开发,实验验证,提供了一些在以前的研究中发现的关键差异的洞察力的支持。电压损失测量是用示波器和微型可穿戴原型来进行的,以捕获非公共接地的影响。结果表明,信道损耗强烈依赖于接收器端的终端阻抗,示波器中不同终端的平均损耗变化高达4dB,与示波器测量相比,可穿戴原型的信道损耗增加了9dB。测量的电容终端通道响应降低了低频损耗,并允许低至13 KHz的平带传递函数,将人体建立为宽带通信通道。对测量结果和仿真模型的分析表明:(1)高阻抗(2)容性端接应用于接收端,以便在低频下准确测量HBC通道的电压模损耗。

英文摘要:

Human Body Communication (HBC) has emerged as an alternative to radio wave communication for connecting low power, miniaturized wearable and implantable devices in, on and around the human body which uses the human body as the communication channel. Previous studies characterizing the human body channel has reported widely varying channel response much of which has been attributed to the variation in measurement setup. This calls for the development of a unifying bio physical model of HBC supported by in depth analysis and an understanding of the effect of excitation, termination modality on HBC measurements. This paper characterizes the human body channel up to 1MHz frequency to evaluate it as a medium for broadband communication. A lumped bio physical model of HBC is developed, supported by experimental validations that provides insight into some of the key discrepancies found in previous studies. Voltage loss measurements are carried out both with an oscilloscope and a miniaturized wearable prototype to capture the effects of non common ground. Results show that the channel loss is strongly dependent on the termination impedance at the receiver end, with up to 4dB variation in average loss for different termination in an oscilloscope and an additional 9 dB channel loss with wearable prototype compared to an oscilloscope measurement. The measured channel response with capacitive termination reduces low frequency loss and allows flat band transfer function down to 13 KHz, establishing the human body as a broadband communication channel. Analysis of the measured results and the simulation model shows that (1) high impedance (2) capacitive termination should be used at the receiver end for accurate voltage mode loss measurements of the HBC channel at low frequencies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑