Ar-CO $_2$、Ne-CO $_2$和Ne-CO $_2$-N $_{2}$混合物中离子迁移率的测量及水含量的影响
Ion mobility measurements in Ar-CO$_2$, Ne-CO$_2$, and Ne-CO$_2$-N$_{2}$ mixtures, and the effect of water contents
摘要:
本文介绍了一种在室温和常压下测量混合气体离子迁移率的探测器。该检测器由一个标准的三重GEM放大区和一个离子漂移区组成。本文提出了一种通过对阴极线栅记录信号进行微分来测量离子到达阴极线栅时间的方法。仿真结果证明了该方法的准确性和鲁棒性。测量了不同气体混合物中的离子迁移率,同时施加范围从200 V cm $^{-1}$到1100 V cm $^{-1}$的不同漂移场值。根据Blanc定律的外推,我们发现在纯氩中漂移(团簇)离子种类的约化迁移率为$1.94\pm0.01$ cm $^{2}$ V $^{-1}$ s $^{-1}$,在纯二氧化碳中为$1.10\pm0.01$ cm $^{2}$ V $^{-1}$ s $^{-1}$。用同样的方法对氖-CO $_2$进行测量,分别得到纯氖和二氧化碳中约化迁移率的$4.06\pm0.07$ cm $^{2}$ V $^{-1}$ s $^{-1}$和$1.09\pm0.01$ cm $^{2}$ V $^{- 1}$ s $^{-1}$。N-PDMATHAMN与Ne-CO-PDMATHAMN的混合物在一定程度上降低了迁移率。对于未来ALICE时间投影室的基线气体混合物,Ne- CO $_2$ -N $_{2}$(90-10-5),漂移离子的测量的约化迁移率为$2.92\pm0.04$ cm $^{2}$ V $^{-1}$ s $^{-1}$。使用Ar-CO $_2$(90-10)和Ne-CO $_2$(90 - 10)检查气体中从70 ppm至约2000 ppm的不同水含量的离子迁移率。加入几百ppm的水后,观察到离子迁移率略有下降。
英文摘要:
A detector has been constructed for measuring ion mobilities of gas mixtures at atmospheric pressure and room temperature. The detector consists of a standard triple GEM amplification region and a drift region where ions drift. A method has been developed to measure the ions' arrival time at a cathode wire-grid by differentiating the recorded signals on this electrode. Simulations prove that this method is accurate and robust. The ion mobility in different gas mixtures is measured while applying different drift field values ranging from 200 V cm$^{-1}$ to 1100 V cm$^{-1}$. From an extrapolation of a Blanc's law fit to measurements in Ar-CO$_2$ mixtures we find the reduced mobility of the drifting (cluster) ion species in pure argon to be $1.94\pm0.01$ cm$^{2}$ V$^{-1}$ s$^{-1}$ and in pure carbon-dioxide to be $1.10\pm0.01$ cm$^{2}$ V$^{-1}$ s$^{-1}$. Applying the same procedure to our measurements in Ne-CO$_2$ yields $4.06\pm0.07$ cm$^{2}$ V$^{-1}$ s$^{-1}$ and $1.09\pm0.01$ cm$^{2}$ V$^{- 1}$ s$^{-1}$ for the reduced mobilities in pure neon and carbon-dioxide, respectively. Admixtures of N$_2$ to Ne-CO$_2$ reduce somewhat the mobility. For the baseline gas mixture of the future ALICE Time Projection Chamber, Ne- CO$_2$-N$_{2}$ (90-10-5), the measured reduced mobility of the drifting ions is $2.92\pm0.04$ cm$^{2}$ V$^{-1}$ s$^{-1}$. Ion mobilities are examined for different water content ranging from 70 ppm to about 2000 ppm in the gas using Ar-CO$_2$ (90-10) and Ne-CO$_2$ (90-10). A slight decrease of ion mobility is observed for the addition of several hundred ppm of water.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。