arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1804.09102cs.CV
收藏

使用全卷积神经网络的胎儿超声自动头部生物测定的人类水平性能

Human-level Performance On Automatic Head Biometrics In Fetal Ultrasound Using Fully Convolutional Neural Networks

Imperial College London(帝国理工学院);ETH Zurich(苏黎世联邦理工学院);Guy’s and St Thomas’ NHS Foundation(盖伊和圣托马斯国民保健服务基金会)
Matthew Sinclair, Christian F. Baumgartner, Jacqueline Matthew, Wenjia Bai, Juan Cerrolaza Martinez, Yuanwei Li, Sandra Smith, Caroline L. Knight, Bernhard Kain… 展开作者

Matthew Sinclair, Christian F. Baumgartner, Jacqueline Matthew, Wenjia Bai, Juan Cerrolaza Martinez, Yuanwei Li, Sandra Smith, Caroline L. Knight, Bernhard Kainz, Jo Hajnal, Andrew P. King, Daniel Rueckert

摘要:

从胎儿超声图像中测量头部生物特征对于监测胎儿的健康发育具有重要意义。然而,相关解剖结构的准确测量在临床中受到较大的观察者间差异的影响。为了解决这个问题,提出了一种利用全卷积网络(FCN)来确定胎儿头围(HC)和双顶径(BPD)测量值的自动化方法。在常规筛查检查期间,在头部的大约2000个2D超声图像上训练FCN,所述图像具有由45个不同的超声医师提供的注释,以执行头部的语义分割。椭圆被拟合到所得到的分割轮廓,以模仿通常由声谱仪操作员产生的注释。该模型的性能与观察者间的变异性进行了比较,其中两位专家手动注释了100张测试图像。HC的平均绝对模型专家误差略优于观察者间误差(1.99 mm vs 2.16 mm),BPD(0.61 mm vs 0.59 mm)以及Dice系数(0.980 vs 0.980)相当。我们的研究结果表明,该模型的性能与人类专家相似,并学会从由许多超声医师注释的大型数据集中产生准确的预测。此外,在GPU上以15 fps的速度近实时生成测量结果,这可以加快熟练和实习超声医师的临床工作流程。

英文摘要:

Measurement of head biometrics from fetal ultrasonography images is of key importance in monitoring the healthy development of fetuses. However, the accurate measurement of relevant anatomical structures is subject to large inter-observer variability in the clinic. To address this issue, an automated method utilizing Fully Convolutional Networks (FCN) is proposed to determine measurements of fetal head circumference (HC) and biparietal diameter (BPD). An FCN was trained on approximately 2000 2D ultrasound images of the head with annotations provided by 45 different sonographers during routine screening examinations to perform semantic segmentation of the head. An ellipse is fitted to the resulting segmentation contours to mimic the annotation typically produced by a sonographer. The model's performance was compared with inter-observer variability, where two experts manually annotated 100 test images. Mean absolute model-expert error was slightly better than inter-observer error for HC (1.99mm vs 2.16mm), and comparable for BPD (0.61mm vs 0.59mm), as well as Dice coefficient (0.980 vs 0.980). Our results demonstrate that the model performs at a level similar to a human expert, and learns to produce accurate predictions from a large dataset annotated by many sonographers. Additionally, measurements are generated in near real-time at 15fps on a GPU, which could speed up clinical workflow for both skilled and trainee sonographers.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑