一种无线仪器适配器的设计与实现
Design and implementation of a wireless instrument adapter
摘要:
评估微创机器人手术中的控制和操作新方法需要一个现实的设置。为了将方法评价与整体临床系统分离,我们提出了一种用于da Vinci手术系统S线EndoWrist \c{opyright}工具的工具适配器。适配器体积小,重量轻,可以安装到任何机器人模仿运动。我们描述了它的设计和实现,以及设置校准仪器,研究精确的运动控制。我们的研究结果表明,每个仪器需要单独校准。校准表明系统不是完全线性的。在相同的旋转方向上的姿态的可重复性具有0.27°的RMSE,并且在三次测量中平均的俯仰和偏航的标准差分别低于0.3°和4.7°。当比较顺时针和逆时针方向上的相同姿态时,俯仰和偏航的RMSE分别为12.8°和5.7°。这可能是由于电机滞后。
英文摘要:
The evaluation of new methods for control and manipulation in minimally invasive robotic surgery requires a realistic setup. To decouple the evaluation of methods from overall clinical systems, we propose an instrument adapter for the S line EndoWrist\c{opyright} instruments of the da Vinci surgical system. The adapter is small and lightweight and can be mounted to any robot to mimic motion. We describe its design and implementation, as well as a setup to calibrate instruments to study precise motion control. Our results indicate that each instrument requires individual calibration. The calibration shows that the system is not fully linear. The repeatability of poses in the same sense of rotation has an RMSE of 0.27°/ and a standard deviation below 0.3° for pitching and 4.7° for yawing averaged over three measurements. When comparing the same poses in clockwise and counter-clockwise direction the RMSE is 12.8° and 5.7° for pitching and yawing, respectively. This is likely due to motor hysteresis.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。