arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1804.01298physics.app-phcond-mat.mtrl-sci
收藏

用于智能小型化仪器的高性能柔性磁性隧道结

High-Performance Flexible Magnetic Tunnel Junctions for Smart Miniaturized Instruments

Selma. Amara, Gallo. A. Torres Sevilla, Mayyada. Hawsawi, Yousof. Mashraei, Hanan . Mohammed, Melvin E. Cruz, Yurii. P. Ivanov, Samridh. Jaiswal, Gerhard. Jakob… 展开作者

Selma. Amara, Gallo. A. Torres Sevilla, Mayyada. Hawsawi, Yousof. Mashraei, Hanan . Mohammed, Melvin E. Cruz, Yurii. P. Ivanov, Samridh. Jaiswal, Gerhard. Jakob, Mathias. Kläui, Muhammad. Hussain, Jurgen. Kosel

摘要:

柔性电子是一个新兴的领域,在许多应用中,从体内生物医学设备到可穿戴智能系统。符合曲面的能力为将电子元件添加到小型化仪器打开了大门,其中尺寸和重量是关键参数。鉴于柔性磁传感器在传感器市场上的流行,柔性磁传感器在这一进步中发挥着重要作用。对于许多高性能应用,磁性隧道结(MTJ)已成为首选,由于其高灵敏度,低功耗等MTJ也是非易失性下一代数据存储介质的有前途的候选人,因此,可能成为可穿戴电子设备的核心组件。在这项工作中,一个通用的低成本的再生批量制造工艺被用来转换刚性MTJ在500 μm的硅晶片衬底到5 μm薄,机械柔性硅器件,并确保整个基板的最佳利用率。这种方法保持了出色的磁性能,这是唯一获得的沉积的MTJ上光滑的高品质的硅晶片。柔性MTJ具有高度可靠性和抗机械应力能力。直径小至500 μm的MTJ叠层的弯曲是可能的,而不影响其性能,并且已经证明了超过1000次循环而不疲劳的耐久性。将柔性MTJ安装在直径为2 mm的心脏导管的尖端上,而不影响其性能。这使得能够以4.93%/Oe的高灵敏度和0.15 μW的低功耗检测磁场及其施加的角度,同时仅分别增加导管的重量和直径8 μg和15 μm。

英文摘要:

Flexible electronics is an emerging field in many applications ranging from in vivo biomedical devices to wearable smart systems. The capability of conforming to curved surfaces opens the door to add electronic components to miniaturized instruments, where size and weight are critical parameters. Given their prevalence on the sensors market, flexible magnetic sensors play a major role in this progress. For many high-performance applications, magnetic tunnel junctions (MTJs) have become the first choice, due to their high sensitivity, low power consumption etc. MTJs are also promising candidates for non-volatile next-generation data storage media and, hence, could become central components of wearable electronic devices. In this work, a generic low-cost regenerative batch fabrication process is utilized to transform rigid MTJs on a 500 μm silicon wafer substrate into 5 μm thin, mechanically flexible silicon devices, and ensuring optimal utilization of the whole substrate. This method maintains the outstanding magnetic properties, which are only obtained by deposition of the MTJ on smooth high-quality silicon wafers. The flexible MTJs are highly reliable and resistive to mechanical stress. Bending of the MTJ stacks with a diameter as small as 500 μm is possible without compromising their performance and an endurance of over 1000 cycles without fatigue has been demonstrated. The flexible MTJs were mounted onto the tip of a cardiac catheter with 2 mm in diameter without compromising their performance. This enables the detection of magnetic fields and the angle which they are applied at with a high sensitivity of 4.93 %/Oe and a low power consumption of 0.15 μW, while adding only 8 μg and 15 μm to the weight and diameter of the catheter, respectively.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑