用多阴极计数器寻找暗光子的冷暗物质
Looking for Hidden Photon's Cold Dark Matter By Multi-Cathode Counter
摘要:
从多阴极计数器的阴极发射的单电子的暗率可以解释为来自冷暗物质(CDM)的隐藏光子(HP)的效应。作为试验性方法,在计数器的不同温度下进行测量。给出了用铜阴极计数器测量的初步结果。对于金属表面隐光子到实光子的假设转换以及由此产生的单电子发射,在2 σ处得到了参数ksi^2的上限为4.3 × 10 -23,该工作被认为是该方法的一个纯粹的例证,并讨论了未来利用多阴极计数器寻找超光子的前景。
英文摘要:
The dark rate of single-electrons emitted from a cathode of a multi-cathode counter may be interpreted as the effect from Hidden Photons (HPs) of Cold Dark Matter (CDM). As a tentative approach the measurements have been performed at different temperatures of the counter. Preliminary results of measurements by using a counter with a copper cathode are presented. An upper limit of 4.3x10-23 for parameter ksi^2 at 2 sigma has been obtained for hypothetical conversion of hidden photon to real photon at the metallic surface with the resulting emission of single electron. The work is considered as a pure illustration of the method and the perspectives are discussed for future search of HPs by a multi-cathode counter.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。