arXiv 1801.10333physics.app-ph
收藏

90 nm节点VLSI单金属触点开路导致扫描链失效的根本原因分析及纠正

Root Cause Analysis and Correction of Single Metal Contact Open-Induced Scan Chain Failure in 90nm node VLSI

Chao-Cheng Ting, Ya-Chi Liu, Hsuan-Hsien Chen, Chung-Ching Tsai, Liwen Shih

摘要:

本文首次报道了基于电子束吸收电流(EBAC)技术和扫描诊断技术的90nm节点SOC金属接触开路定位。根据从X射线能量色散谱(EDX)获得的检测到的过量碳、硅和氧信号,认为失效是由于在镀铜之前的O2等离子体干法清洁期间形成的硅酸盐光致抗蚀剂聚合物的不完全去除引起的。基于此,我们提出在镀铜之前用稀释的HF清洗代替干法清洗,这可以显著地去除硅酸盐聚合物并提高产率。

英文摘要:

In this paper, the localization of open metal contact for 90nm node SOC is reported based on Electron Beam Absorbed Current (EBAC) technique and scan diagnosis for the first time. According to the detected excess carbon, silicon and oxygen signals obtained from X-ray energy dispersive spectroscopy (EDX), the failure was deemed to be caused by the incomplete removal of silicate photoresist polymer formed during the O2 plasma dry clean before copper plating. Based on this, we proposed to replace the dry clean with diluted HF clean prior to the copper plating, which can significantly remove the silicate polymers and increase the yield.