利用混合泊松-高斯噪声模型进行统计图像重建用于X射线CT
Statistical Image Reconstruction Using Mixed Poisson-Gaussian Noise Model for X-Ray CT
AI总结:
本文提出混合泊松-高斯(MPG)模型用于超低剂量CT图像重建,通过直接处理非正数据减少噪声和偏倚,提升图像质量。
摘要:
统计图像重建(SIR)方法在X射线CT中能产生高质量且准确的图像,同时显著减少患者辐射暴露。当进一步降低X射线剂量至极低水平时,光子饥饿现象发生,电子噪声开始主导,导致原始测量中出现非正值。这些非正值对需要对原始数据取对数的后对数SIR方法构成挑战,并可能导致使用简单修正方法处理这些非正原始测量时产生伪影。在极低剂量下,原始数据显著偏离预对数数据的泊松或移位泊松统计,以及后对数数据的高斯统计。本文提出了一种新的SIR方法,称为MPG(混合泊松-高斯)。MPG使用混合泊松-高斯分布建模原始噪声测量,以考虑量子噪声和电子噪声。MPG能够直接使用原始数据中的负值和零值,而无需任何预处理。MPG成本函数包含重新加权最小二乘数据拟合项、边缘保持正则化项和非负性约束项。我们使用交替方向乘子法(ADMM)将MPG优化问题分解为几个更容易解决的子问题。在3D模拟锥形束数据集和由临床数据生成的合成螺旋数据集上的结果表明,所提出的MPG方法在超低剂量CT(ULDCT)成像中相比传统滤波反投影(FBP)、加权最小型(PWLS)和移位泊松(SP)方法减少了噪声并降低了重建图像的偏倚。
英文摘要:
Statistical image reconstruction (SIR) methods for X-ray CT produce high-quality and accurate images, while greatly reducing patient exposure to radiation. When further reducing X-ray dose to an ultra-low level by lowering the tube current, photon starvation happens and electronic noise starts to dominate, which introduces negative or zero values into the raw measurements. These non-positive values pose challenges to post-log SIR methods that require taking the logarithm of the raw data, and causes artifacts in the reconstructed images if simple correction methods are used to process these non-positive raw measurements. The raw data at ultra-low dose deviates significantly from Poisson or shifted Poisson statistics for pre-log data and from Gaussian statistics for post-log data. This paper proposes a novel SIR method called MPG (mixed Poisson-Gaussian). MPG models the raw noisy measurements using a mixed Poisson-Gaussian distribution that accounts for both the quantum noise and electronic noise. MPG is able to directly use the negative and zero values in raw data without any pre-processing. MPG cost function contains a reweighted least square data-fit term, an edge preserving regularization term and a non-negativity constraint term. We use Alternating Direction Method of Multipliers (ADMM) to separate the MPG optimization problem into several sub-problems that are easier to solve. Our results on 3D simulated cone-beam data set and synthetic helical data set generated from clinical data indicate that the proposed MPG method reduces noise and decreases bias in the reconstructed images, comparing with the conventional filtered back projection (FBP), penalized weighted least-square (PWLS) and shift Poisson (SP) method for ultra-low dose CT (ULDCT) imaging.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。