arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1801.08668stat.APq-bio.QM
收藏

使用可穿戴活动监测器的数据监测膝关节骨关节炎患者的身体功能

Monitoring physical function in patients with knee osteoarthritis using data from wearable activity monitors

Vibhu Agarwal, Matthew Smuck, Nigam H Shah

摘要:

目前用于身体功能的临床评估不能客观地量化日常生活中的日常活动。可穿戴活动监测器能够客观测量日常活动,但不能映射到临床测量的身体表现指标。我们将身体功能表示为通过可穿戴活动监测器获得的分钟级活动数据得出的日常活动曲线。我们使用骨关节炎倡议(OAI)的数据构建每日活动曲线,表示连续几天在一组活动类中花费的平均时间。使用日常活动概况作为输入,我们训练了统计模型,该模型将受试者分类为通过400米步行测试、20米步行测试和5次坐立测试测量的身体功能的客观测量的四分位数。我们评估了模型的性能,从同一日历年的数据,用于训练的模型,以及活动数据的未来两年。日常活动概况预测通过临床评估测量的身体表现。使用现有数据,对于400米步行、20米步行和5次坐立试验,在第一四分位数中分类性能值获得的AUC分别为0.79、0.78和0.72。对于第四个四分位数中的分类性能值,获得的AUC分别为0.77、0.66和0.73。对未来两年的数据进行评估,对于20米步速测试和5次坐立测试,获得的最高AUC分别为第一四分位数的0.77和0.68,第四四分位数的0.75和0.70。我们可以构建代表实际身体功能的活动曲线,如活动曲线和临床测量的身体表现测量之间的关系所证明的。经由所描述的活动简档测量身体表现可以实现对患者的远程功能监测。

英文摘要:

Currently used clinical assessments for physical function do not objectively quantify daily activities in routine living. Wearable activity monitors enable objective measurement of routine daily activities, but do not map to clinically measured physical performance measures. We represent physical function as a daily activity profile derived from minute-level activity data obtained via a wearable activity monitor. We construct daily activity profiles representing average time spent in a set of activity classes over consecutive days using the Osteoarthritis Initiative (OAI) data. Using the daily activity profile as input, we trained statistical models that classify subjects into quartiles of objective measurements of physical function as measured via the 400m walk test, the 20m walk test and 5 times sit stand test. We evaluated model performance on held out data from the same calendar year as that used to train the models as well as on activity data two years into the future. The daily activity profile predicts physical performance as measured via clinical assessments. Using held out data, the AUC obtained in classifying performance values in the 1st quartile was 0.79, 0.78 and 0.72, for the 400m walk, the 20m walk and 5 times sit stand tests. For classifying performance values in the 4th quartile, the AUC obtained was 0.77, 0.66 and 0.73 respectively. Evaluated on data from two years into the future, for the 20m pace test and the 5 times sit stand tests, the highest AUC obtained was 0.77 and 0.68 for the 1st quartile and 0.75 and 0.70 for the 4th quartile respectively. We can construct activity profiles representing actual physical function as demonstrated by the relationship between the activity profiles and the clinically measured physical performance measures. Measurement of physical performance via the activity profile as described can enable remote functional monitoring of patients.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑