摘要:

可变串联电抗器(VSR)可以通过调节线路电抗来有效地控制潮流。当它们在电网中得到适当的分配时,可以减少输电阻塞和发电成本。本文提出了一个规划模型,以最佳分配的VSR考虑AC约束和多个场景,包括基本情况和意外事件。该规划模型是一个非凸的大规模混合整数非线性规划问题,通常是难以求解的。Benders方法将MINLP模型分解为一个混合整数线性规划(MILP)主问题和若干非线性子问题。基于IEEE 118节点的算例表明了该方法的有效性。

英文摘要:

The Variable Series Reactors (VSRs) can efficiently control the power flow through the adjustment of the line reactance. When they are appropriately allocated in the power network, the transmission congestion and generation cost can be reduced. This paper proposes a planning model to optimally allocate VSRs considering AC constraints and multi-scenarios including base case and contingencies. The planning model is originally a non-convex large scale mixed integer nonlinear program (MINLP), which is generally intractable. The proposed Benders approach decomposes the MINLP model into a mixed integer linear program (MILP) master problem and a number of nonlinear subproblems. Numerical case studies based on IEEE 118-bus demonstrate the high performance of the proposed approach.