双能兆伏级X线摄影对货物物质分解成像的研究

Material Decomposed Cargo Imaging with Dual Energy Megavoltage Radiography

Polad M. Shikhaliev

摘要:

利用兆伏射线照相术进行货物成像对于探测非法材料具有重要的应用。它能够通过在两种不同的X射线能量或双能(DE)射线照相术下对货物进行成像来分解和量化具有不同原子序数的材料。单能量和DE射线照相术的性能取决于射束能量、射束过滤、辐射剂量、物体尺寸和物体内容。这项工作的目的是进行全面的定性和定量调查的图像质量在MV射线照相取决于上述参数。设计了一个数字化体模,包括厚度为2cm、6cm和18 cm的Fe背景,以及聚乙烯、Fe、Pb和U材料样品。在X射线束能量3.5MV、6 MV和9 MV下生成单能量图像。DE材料分解图像使用交错的低和高能量束3.5/6 MV和6/9 MV生成。X射线束通过具有可变厚度的低Z(聚乙烯)和高Z(Pb)过滤器过滤。加速器的辐射输出对于所有束能量保持恒定。图像质量度量是特定样品在特定背景上的信噪比(SNR)。发现SNR以复杂的方式取决于上述参数,但是可以通过选择特定的参数集合来优化。对于某些成像设置,增加滤波器厚度,同时强烈吸收光束,增加材料分解图像的SNR。由于多能X射线光谱导致的射束硬化导致材料分解误差,但这可以使用感兴趣区域分解来解决。结果表明,用DE法分离原子序数相近的物质是不可行的。特别是铅和铀很难分解,至少在辐射源和安全要求允许的剂量水平下是这样。

英文摘要:

Cargo imaging with Megavoltage (MV) radiography has important applications for detecting illicit materials. It enables decomposing and quantifying materials with different atomic numbers by imaging cargo at two different x-ray energies, or dual energy (DE) radiography. The performance of both single energy and DE radiography depends on beam energy, beam filtration, radiation dose, object size, and object content. The purpose of this work was to perform comprehensive qualitative and quantitative investigations of the image quality in MV radiography depending on the above parameters. A digital phantom was designed including Fe background with thicknesses of 2cm, 6cm, and 18cm, and materials samples of Polyethylene, Fe, Pb, and U. The single energy images were generated at x-ray beam energies 3.5MV, 6MV, and 9MV. The DE material decomposed images were generated using interlaced low and high energy beams 3.5/6MV and 6/9MV. The x-rays beams were filtered by low-Z (Polyethylene) and high-Z (Pb) filters with variable thicknesses. The radiation output of the accelerator was kept constant for all beam energies. The image quality metrics was signal-to-noise ratio (SNR) of the particular sample over a particular background. It was found that the SNR depends on the above parameters in a complex way, but can be optimized by selecting a particular set of parameters. For some imaging setups increased filter thicknesses, while strongly absorbed the beams, increased the SNR of material decomposed images. Beam hardening due to polyenergetic x-ray spectra resulted in material decomposition errors, but this could be addressed using region of interest decomposition. It was shown that it is not feasible to separate the materials with close atomic numbers using the DE method. Particularly, Pb and U were difficult to decompose, at least at the dose levels allowed by radiation source and safety requirements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑