使用高稳定性石英晶体微量天平测量和模拟金属中和金属上气体的化学动力学:金中的氧
Using a high-stability quartz-crystal microbalance to measure and model the chemical kinetics for gases in and on metals: oxygen in gold
摘要:
本文介绍了使用高稳定性的石英晶体微量天平(QCM)来测量石英振荡器上的金属电极上和金属电极中吸附的气体的质量,当气体压力较低时,气体可以被认为是刚性地附着在金属上,因此粘度效应可以忽略不计。这提供了作为时间函数的气体吸收的总质量的绝对测量,其可用于模拟所涉及的动力学过程。该技术可以测量气体在金属中的扩散参数,接近室温,气体压力远低于一个大气压,与表面过程有关,如原子层沉积和多相催化的模型研究,而传统的扩散测量需要温度超过400 ℃,气体压力至少为几托。该方法的一个强有力的方面是能够结合大量的测量吸收质量的QCM与表面敏感的技术,如俄歇电子能谱在同一真空室。该方法使用原子氧进行说明,该原子氧在6x 10 -5 Torr的O2气体下在热钨丝的存在下形成,与保持在52至120 oC的QCM晶体上的金电极相互作用。一些入射的氧气形成表面氧化物,最终阻止更多的吸收,其余的,约80%,扩散。令人惊讶的是,氧摄取的速率最初随着先前吸收的氧的量而增加;因此,仅当氧的预吸附调节样品时,测量的氧摄取随时间的变化是可再现的。可测量的热解吸需要高于130 ° C的温度,但是在这些实验的所有温度下,所有的氧都可以通过CO清除而被去除。简单的动力学模型,拟合实验数据,提取相关参数。
英文摘要:
This paper describes the use of a high-stability quartz-crystal microbalance (QCM) to measure the mass of a gas absorbed on and in the metal electrode on the quartz oscillator, when the gas pressure is low and the gas can be considered as rigidly attached to the metal, so viscosity effects are negligible. This provides an absolute measure of the total mass of gas uptake as a function of time, which can be used to model the kinetic processes involved. The technique can measure diffusion parameters of gases in metals close to room temperature at gas pressures much below one atmosphere, as relevant to surface processes such as atomic layer deposition and model studies of heterogeneous catalysis, whereas traditional diffusion measurements require temperatures over 400oC at gas pressures of at least a few Torr. A strong aspect of the method is the ability to combine the bulk measurement of absorbed mass by a QCM with a surface-sensitive technique such as Auger electron spectroscopy in the same vacuum chamber. The method is illustrated using atomic oxygen, formed under O2 gas at 6x10-5 Torr in the presence of a hot tungsten filament, interacting with the gold electrode on a QCM crystal held at 52 to 120oC. Some of the incident oxygen forms a surface oxide which eventually blocks more uptake, and the rest, about 80%, indiffuses. Surprisingly, the rate of oxygen uptake initially increases with the amount of oxygen previously absorbed; therefore, the measured oxygen uptake with time is reproducible only if pre-adsorption of oxygen conditions the sample. Temperatures above 130oC are necessary for measurable thermal desorption, but all the oxygen can be removed by CO scavenging at all temperatures of these experiments. Simple kinetic models are developed for fitting the experimental data to extract relevant parameters.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。