来自“See Change”的第一个弱透镜结果:量化两个Z>1.5高红移星系团SPT-CL J2040-4451和IDCS J1426 +3508中的暗物质
First Weak-lensing Results from "See Change": Quantifying Dark Matter in the Two Z>1.5 High-redshift Galaxy Clusters SPT-CL J2040-4451 and IDCS J1426+3508
摘要:
我们分别在z=1.48和1.75处对SPT-CLJ 2040 -4451和IDCSJ 1426 +3508进行了弱透镜研究。这两个星系团是在我们的“See Change”计划中观测到的,该计划是对12个大质量高红移星系团的HST调查,旨在测量高z超新星和精确估算星系团质量的弱透镜。我们使用WFC 3的红外图像检测到微弱但显著的星系形状扭曲,该图像尚未用于弱透镜研究。这两个星系团似乎都具有宽松的形态投影质量分布,它们的质量质心很好地同意与星系光度和X射线发射所定义的。使用NFW曲线,我们假设质量与浓度参数密切相关,我们确定SPT-CL J2040-4451和IDCS J1426+3508的质量分别为M_{200} =8.6_{-1.4}^{+1.7 x10 ^14 M_sun和2.2_{-0.7}^{+1.1 x10 ^14 M_sun。SPT-CLJ 2040 -4451的弱透镜质量表明该星团显然是一个罕见的天体。采用中心值,这样一个z>1.48的大质量星系团的预期丰度在母体2500 sq中仅为~0.07。°的调查.然而,它还为时过早,声称这个集群的存在下,目前的LCDM范式造成了严重的紧张局势,除非这种紧张局势将继续在未来的研究后,边缘化的许多来源的不确定性,如质量函数的准确性和质量浓度的关系在高质量端。IDCSJ 1426 +3508的质量与我们之前基于ACS的弱透镜结果非常一致,而来自我们WFC 3成像数据的高得多的源密度使当前的统计不确定性降低了约40%。
英文摘要:
We present a weak-lensing study of SPT-CLJ2040-4451 and IDCSJ1426+3508 at z=1.48 and 1.75, respectively. The two clusters were observed in our "See Change" program, a HST survey of 12 massive high-redshift clusters aimed at high-z supernova measurements and weak-lensing estimation of accurate cluster masses. We detect weak but significant galaxy shape distortions using IR images from the WFC3, which has not yet been used for weak-lensing studies. Both clusters appear to possess relaxed morphology in projected mass distribution, and their mass centroids agree nicely with those defined by both the galaxy luminosity and X-ray emission. Using an NFW profile, for which we assume that the mass is tightly correlated with the concentration parameter, we determine the masses of SPT-CL J2040-4451 and IDCS J1426+3508 to be M_{200}=8.6_{-1.4}^{+1.7}x10^14 M_sun and 2.2_{-0.7}^{+1.1}x10^14 M_sun, respectively. The weak-lensing mass of SPT-CLJ2040-4451 shows that the cluster is clearly a rare object. Adopting the central value, the expected abundance of such a massive cluster at z>1.48 is only ~0.07 in the parent 2500 sq. deg. survey. However, it is yet premature to claim that the presence of this cluster creates a serious tension with the current LCDM paradigm unless that tension will remain in future studies after marginalizing over many sources of uncertainties such as the accuracy of the mass function and the mass-concentration relation at the high mass end. The mass of IDCSJ1426+3508 is in excellent agreement with our previous ACS-based weak-lensing result while the much higher source density from our WFC3 imaging data makes the current statistical uncertainty ~40% smaller.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。