基于电流传感器SQUID的模块化、可扩展、耐场多通道矢量磁力仪

A modular, extendible and field-tolerant multichannel vector magnetometer based on current sensor SQUIDs

Jan-Hendrik Storm, Dietmar Drung, Martin Burghoff, Rainer Körber

摘要:

我们提出了我们的可扩展和强大的多通道SQUID磁强计系统的原型模块。多模块布置可以通过使用多达7个模块来实现。它用于生物磁性和自旋进动的高精度测量。更高要求的应用是磁弛豫测量和超低场核磁共振(ULF NMR),其中通常施加高达100 mT的脉冲场。该系统在柏林磁屏蔽室内运行,并配备了18个由铌(Nb)线绕拾波线圈组成的磁力计。总共16个直径为17.1 mm的小型拾波线圈形成了一个规则的网格,每个网格都有单独的通道,以确保系统灵敏度覆盖所有三个正交的空间方向。两个大的六边形拾波线圈的等效直径为74.5 mm,敏感的z方向围绕在两个不同的高度的网格,适合于深源的检测。每个线圈通过可拆卸的超导触点连接到薄膜Nb SQUID电流传感器的输入端。SQUID配备了集成的输入电流限制器。进入拾波线圈的反馈使通道之间的串扰最小化。电流传感器芯片封装包括Nb的超导屏蔽。通过数值模拟分析了样机和多模块布置的场畸变。小型磁力计的测量噪声在0.6和1.5 fT/Hz $^{1/2}$之间,大型磁力计的测量噪声远低于1 fT/Hz $^{1/2}$。使用软件梯度计,我们实现了0.54 fT/Hz $^{1/2}$的最小噪声水平。我们进行了超低频核磁共振实验,验证系统的鲁棒性对脉冲场,和脑磁图(MEG)体感诱发神经元活动。我们的18通道原型的低噪声性能使MEG能够检测约1 kHz的高频分量。

英文摘要:

We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and spin precession. Further demanding applications are magnetorelaxometry and ultra-low-field nuclear magnetic resonance (ULF NMR), where pulsed fields of up to 100 mT are typically applied. The system is operated inside the Berlin Magnetically Shielded Room and equipped with 18 magnetometers consisting of niobium (Nb) wire-wound pick-up coils. A total of 16 small pick-up coils with 17.1 mm diameter form a regular grid with individual channels arranged to ensure system sensitivity covers all three orthogonal spatial directions. Two large hexagonal pick-up coils with an equivalent diameter of 74.5 mm sensitive in z-direction surround the grid at two different heights and are suitable for the detection of deep sources. Each coil is connected to the input of a thin-film Nb SQUID current sensor via a detachable superconducting contact. The SQUIDs are equipped with integrated input current limiters. Feedback into the pick-up coils minimizes crosstalk between channels. The current sensor chip package includes a superconducting shield of Nb. The field distortion of the prototype and a multi-module arrangement was analysed by numerical simulation. The measured noise of the small magnetometers was between 0.6 and 1.5 fT/Hz$^{1/2}$, and well below 1 fT/Hz$^{1/2}$ for the large ones. Using a software gradiometer, we achieved a minimum noise level of 0.54 fT/Hz$^{1/2}$. We performed ULF NMR experiments, verifying the system's robustness against pulsed fields, and magnetoencephalographgy (MEG) on somatosensory evoked neuronal activity. The low noise performance of our 18-channel prototype enabled the detection of high-frequency components at around 1 kHz by MEG.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑