使用$^{87}$ Rb检测和去耦的$^{3}$ He- $^{129}$氦同位素测磁仪
$^{3}$He-$^{129}$Xe Comagnetometery using $^{87}$Rb Detection and Decoupling
摘要:
本文描述了一种利用$^{87}$ Rb原子对惰性气体自旋极化和探测的$^{3}$ He- $^{129}$超导磁敏计。我们利用一训练$^{87}$ Rb $π$脉冲和$σ^+/σ^-$光抽运实现了具有自旋交换弛豫抑制的有限场Rb磁强计。我们通过在黑暗中测量$^{3}$ He和$^{129}$的自旋旋进频率来抑制极化Rb的频移,同时沿两个方向施加$π$脉冲来使Rb原子去旋。旋转$π$脉冲的平面以抑制核自旋的布洛赫-西格特位移。我们测量$^{3}$ He与$^{129}$的自旋进动频率之比,其绝对精度足以在不改变comagnetometer方向的情况下解决地球自转问题。在积分8小时后实现了7 nHz的频率分辨率,没有明显漂移的证据。
英文摘要:
We describe a $^{3}$He-$^{129}$Xe comagnetometer using $^{87}$Rb atoms for noble-gas spin polarization and detection. We use a train of $^{87}$Rb $π$ pulses and $σ^+/σ^-$ optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation. We suppress frequency shifts from polarized Rb by measuring the $^{3}$He and $^{129}$Xe spin precession frequencies in the dark, while applying $π$ pulses along two directions to depolarize Rb atoms. The plane of the $π$ pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins. We measure the ratio of $^{3}$He to $^{129}$Xe spin precession frequencies with sufficient absolute accuracy to resolve the Earth's rotation without changing the orientation of the comagnetometer. A frequency resolution of 7 nHz is achieved after integration for 8 hours without evidence of significant drift.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。