摘要:

提高激光烧蚀电感耦合等离子体质谱(LA-ICP-MS)的空间分辨率是地质样品微量分析中的一个难题。激光束的较小尺寸将允许(1)微量元素组成的高分辨率测定,(2)晶体/熔体分配系数的精确估计,(3)扩散分布的详细表征,和(4)精细火山玻璃的分析。在这里,我们报告了LA-ICP四极杆MS的品质因数,其空间分辨率为5 μm。这项研究强调了即使在空间分辨率为5 μm的情况下,也有可能实现地质样品的适当检测限、准确度和精密度。在15 μm的光束尺寸下,精度(以一个sigma测量)和准确度(表示为与参考值的相对偏差)约为10%。在8 μ m的较小光束尺寸下,对于1.7 μg g-1以上的浓度,精度下降到15%。当束流尺寸减小到~5 μm时,以42 Ca和29 Si为内标,对于10 μg g-1以上的浓度,精密度分别下降到约15%和20%。在15 μ m和10 μm的光束尺寸下,精度分别优于或等于10%和13%。当空间分辨率提高到8 μm时,以42 Ca和29 Si为内标,准确度分别优于15%和20%。我们采用这种高分辨率的技术来研究2010年埃亚菲亚德拉火山爆发的火山灰颗粒中的火山玻璃。我们的结果与以前报道的在较低空间分辨率下获得的数据一致,支持了该方法的可靠性。

英文摘要:

Increasing the spatial resolution of Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) is a challenge in microanalysis of geological samples. Smaller sizes for the laser beam will allow for (1) high resolution determination of trace element compositions, (2) accurate estimation of crystal/melt partition coefficients, (3) detailed characterization of diffusion profiles, and (4) analysis of fine volcanic glasses. Here, we report about the figures of merit for LA-ICP Quadrupole MS down to a spatial resolution of 5 μm. This study highlights the possibility to achieve suitable limits of detection, accuracy and precision for geological samples even at spatial resolutions of the order of 5 μm. At a beam size of 15 μm precision (measured as one sigma) and accuracy (expressed as relative deviation from the reference value) are of the order of 10%. At a smaller beam size of 8um, precision decreases to 15% for concentration above 1.7 μg g-1. As the beam size is decreased to ~5 μm, precision declines to about 15% and 20% for concentrations above 10 μg g-1 using 42Ca and 29Si as internal standard, respectively. Accuracy is better or equal to 10% and 13 % at beam sizes of 15 and 10 μm respectively. When the spatial resolution is increased to 8 μm, accuracy remains better than 15% and 20% for 42Ca and 29Si as internal standard, respectively. We employed such high-resolution techniques to volcanic glasses in ash particles of the 2010 Eyjafjallajökull eruption. Our results are well consistent with the previously reported data obtained at lower spatial resolution, supporting the reliability of the method.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑