圆极化馈电的全斯托克斯偏振测量. GHz范围内具有稳定线性和circular polarization的源
Full-Stokes polarimetry with circularly polarized feeds - Sources with stable linear and circular polarization in the GHz regime
摘要:
我们提出了一个管道,允许恢复可靠的信息,所有四个斯托克斯参数具有高精度。它的新颖性依赖于治疗的仪器效应之前已经计算的斯托克斯参数相反,传统的方法,如缪勒矩阵之一。仪器线偏振在整个望远镜光束上得到校正,即使在记录信号严重损坏时,也可以恢复显著的斯托克斯$Q$和$U$。我们在偏振度方面达到的精度为0.1- 0.2%的量级。偏振角以几乎1 $^{\circ}$的精度确定。所提出的方法被应用到恢复的线性和圆偏振的约150个活动星系核。2010年7月至2016年4月,Effelsberg 100米望远镜在4.85 GHz和8.35 GHz的频率下监测了这些源,频率约为1.2个月。利用月球的偏振辐射来校准偏振角。我们的分析表明,一个小的系统诱导的旋转约1 $^{\circ}$在两个观察频率。最后,我们确定了五个源显着和稳定的线性偏振;三个源保持恒定的线性非偏振在我们检查的期间内,共有11个源具有稳定的圆偏振度$m_\mathrm{c}$,其中四个非零$m_\mathrm{c}$。我们还确定了八个源,保持一个稳定的偏振角在检查期间。所有这一切都提供给社会偏振观测参考。我们最后表明,我们的分析方法是概念上不同于传统使用的,并表现出更好的Müller矩阵方法。虽然它是为配备圆偏振馈源的系统开发的,但也可以很容易地修改为具有线偏振馈源的系统。
英文摘要:
We present a pipeline that allows recovering reliable information for all four Stokes parameters with high accuracy. Its novelty relies on the treatment of the instrumental effects already prior to the computation of the Stokes parameters contrary to conventional methods, such as the Müller matrix one. The instrumental linear polarization is corrected across the whole telescope beam and significant Stokes $Q$ and $U$ can be recovered even when the recorded signals are severely corrupted. The accuracy we reach in terms of polarization degree is of the order of 0.1-0.2 %. The polarization angles are determined with an accuracy of almost 1$^{\circ}$. The presented methodology was applied to recover the linear and circular polarization of around 150 Active Galactic Nuclei. The sources were monitored from July 2010 to April 2016 with the Effelsberg 100-m telescope at 4.85 GHz and 8.35 GHz with a cadence of around 1.2 months. The polarized emission of the Moon was used to calibrate the polarization angle. Our analysis showed a small system-induced rotation of about 1$^{\circ}$ at both observing frequencies. Finally, we identify five sources with significant and stable linear polarization; three sources remain constantly linearly unpolarized over the period we examined; a total of 11 sources have stable circular polarization degree $m_\mathrm{c}$ and four of them with non-zero $m_\mathrm{c}$. We also identify eight sources that maintain a stable polarization angle over the examined period. All this is provided to the community for polarization observations reference. We finally show that our analysis method is conceptually different from the traditionally used ones and performs better than the Müller matrix method. Although it was developed for a system equipped with circularly polarized feeds it can easily be modified for systems with linearly polarized feeds as well.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。