arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1706.01070physics.ins-detastro-ph.IM
收藏

EDELWEISS-III直接搜寻暗物质实验的性能

Performance of the EDELWEISS-III experiment for direct dark matter searches

E. Armengaud, Q. Arnaud, C. Augier, A. Benoît, L. Bergé, T. Bergmann, J. Billard, T. de Boissière, G. Bres, A. Broniatowski, V. Brudanin, P. Camus, A. Cazes, M.… 展开作者

E. Armengaud, Q. Arnaud, C. Augier, A. Benoît, L. Bergé, T. Bergmann, J. Billard, T. de Boissière, G. Bres, A. Broniatowski, V. Brudanin, P. Camus, A. Cazes, M. Chapellier, F. Charlieux, M. De Jésus, L. Dumoulin, K. Eitel, D. Filosofov, N. Foerster, N. Fourches, G. Garde, J. Gascon, A. Giuliani, M. Grollier, M. Gros, L. Hehn, S. Hervé, G. Heuermann, V. Humbert, Y. Jin, A. Juillard, C. Kéfélian, M. Kleifges, V. Kozlov, H. Kraus, V. A. Kudryavtsev, H. Le-Sueur, J. Lin, R. Maisonobe, M. Mancuso, S. Marnieros, A. Menshikov, X. -F. Navick, C. Nones, E. Olivieri, P. Pari, B. Paul, D. Poda, E. Queguiner, M. Robinson, H. Rodenas, S. Rozov, V. Sanglard, B. Schmidt, S. Scorza, B. Siebenborn, D. Tcherniakhovski, L. Vagneron, M. Weber, E. Yakushev, X. Zhang, A. Zolotarova

摘要:

我们提出的测量结果表明,EDELWEISS-III阵列的低温锗探测器直接暗物质搜索的效率。描述了实验装置和FID(全数字化)检测器阵列,以及背景抑制中热和电离信号的双重测量的效率。对于用于符合研究的整套24个FID探测器,基准电离能的基线分辨率主要低于0.7 keV $_{ee}$(FHWM),而热能的基线分辨率主要低于1.5 keV $_{ee}$(FWHM)。用AmBe源测量了FID设计对核反冲的响应以及很好的鉴别能力。在90% C. L.下,每个$α$的$R_{\rm surf} < 4 \times 10^{-5}$的表面$β$ -和$α$ -衰减抑制能力。已经用$^{210}$ Pb源测定,已经用$^{133}$ Ba源的$γ$ -校准证明了本体$γ$ -射线事件的拒绝,导致$R_{γ{\rm -mis-fid}} < 2.5 \times 10^{-6}$值在90% C.L.。在探测器阵列中测量的天然放射性的当前水平显示为单个$γ$背景的比率。FID检测器的基准体积分数已被测量到使用$^{65}$ Zn和$^{68,71}$ Ge同位素的宇宙成因活化的加权平均值为$(74.6 \pm 0.4)\%$。文中还讨论了探测器响应的稳定性和均匀性。因此,升级后的EDELWEISS-III探测器的分辨率、阈值和背景水平非常适合在大质量范围内直接搜索WIMP暗物质。

英文摘要:

We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $β$- and $α$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $α$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $γ$-ray events has been demonstrated using $γ$-calibrations with $^{133}$Ba sources leading to a value of $R_{γ{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $γ$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑