基于词典的室性早搏监测:一种超低成本的床旁服务
Dictionary-based Monitoring of Premature Ventricular Contractions: An Ultra-Low-Cost Point-of-Care Service
摘要:
虽然心血管疾病(CVD)在各经济阶层中普遍存在,但由于传统CVD管理的高成本,经济上处于不利地位的人群受到不成比例的影响。因此,开发一种即使是经济金字塔底层的群体也负担得起的超低成本替代品已成为社会当务之急。在此背景下,我们提出了一种廉价而准确的家庭心电图(ECG)监测服务。具体而言,我们寻求提供室性早搏(PVC)的即时监测,室性早搏的高频率可能表明潜在致命性心律失常的发作。请注意,传统的远程心脏病学系统获取ECG,将其传输到专业诊断中心而不进行处理,并且几乎达到床边设置的诊断准确性,尽管带宽成本很高。在这种情况下,我们的目标是在不显著牺牲可靠性的情况下降低成本。为此,我们开发了一个基于字典的算法,检测具有高灵敏度的异常节拍,然后才被发送。我们进一步压缩这些传输的节拍使用类特定的字典受到适当的重建/诊断保真度。这种方案不仅可以降低整体带宽要求,还可以定位异常搏动,从而减轻医生的负担。最后,使用Monte Carlo交叉验证MIT/BIH心律失常数据库,我们评估所提出的系统的性能。特别是,在100次心跳中最多一次未检测到PVC的灵敏度目标,以及均方根差百分比小于9%(临床可接受的保真度水平)的情况下,我们实现了带宽成本降低约99.15%,相当于传统远程心脏病学的118倍节省。
英文摘要:
While cardiovascular diseases (CVDs) are prevalent across economic strata, the economically disadvantaged population is disproportionately affected due to the high cost of traditional CVD management. Accordingly, developing an ultra-low-cost alternative, affordable even to groups at the bottom of the economic pyramid, has emerged as a societal imperative. Against this backdrop, we propose an inexpensive yet accurate home-based electrocardiogram(ECG) monitoring service. Specifically, we seek to provide point-of-care monitoring of premature ventricular contractions (PVCs), high frequency of which could indicate the onset of potentially fatal arrhythmia. Note that a traditional telecardiology system acquires the ECG, transmits it to a professional diagnostic centre without processing, and nearly achieves the diagnostic accuracy of a bedside setup, albeit at high bandwidth cost. In this context, we aim at reducing cost without significantly sacrificing reliability. To this end, we develop a dictionary-based algorithm that detects with high sensitivity the anomalous beats only which are then transmitted. We further compress those transmitted beats using class-specific dictionaries subject to suitable reconstruction/diagnostic fidelity. Such a scheme would not only reduce the overall bandwidth requirement, but also localising anomalous beats, thereby reducing physicians' burden. Finally, using Monte Carlo cross validation on MIT/BIH arrhythmia database, we evaluate the performance of the proposed system. In particular, with a sensitivity target of at most one undetected PVC in one hundred beats, and a percentage root mean squared difference less than 9% (a clinically acceptable level of fidelity), we achieved about 99.15% reduction in bandwidth cost, equivalent to 118-fold savings over traditional telecardiology.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。