arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1704.01822astro-ph.CO
收藏

强引力透镜II的广义模型无关表征:多个图像之间的变换矩阵

Generalised model-independent characterisation of strong gravitational lenses II: Transformation matrix between multiple images

Jenny Wagner, Nicolas Tessore

摘要:

我们确定变换矩阵T,该变换矩阵T将具有解析特征的多个图像映射到彼此上,并且该变换矩阵T基于泰勒扩展透镜势,该泰勒扩展透镜势接近我们的模型无关透镜表征方法中的临界曲线上的点。从T,在折叠和尖点的临界曲线的相同的信息是由确定的四极矩的个别图像作为可观的。此外,我们读出图像之间的相对奇偶性,以便在已知一个图像时确定所有图像的奇偶性。我们比较所有可检索的潜在衍生物的比率,实际的和那些通过使用四极矩观察到的星系团尺度奇异等温椭圆产生的两个和三个图像配置。我们的结论是,使用四极矩作为观测量,在尖点的临界曲线的属性被检索到更高的精度,在折叠点的精度较低,和二阶电位导数的比可比的精度。我们表明,使用的收敛率和减少剪切的方法是相当于我们接近的临界曲线,但产生更准确的结果,是更强大的,因为它不需要一个特殊的坐标系一样,使用潜在的衍生物的方法。通过将图像中手动分配的参考点映射到彼此上来确定T。如果参考点的分配受到噪声下的测量不确定性,我们发现,透镜参数的置信区间可以作为值一样大,当不确定性大于一个像素。观察到的多个图像的解决功能比未解决的扩展,因此,高阶矩应考虑到改善重建。

英文摘要:

(shortened) We determine the transformation matrix T that maps multiple images with resolved features onto one another and that is based on a Taylor-expanded lensing potential close to a point on the critical curve within our model-independent lens characterisation approach. From T, the same information about the critical curve at fold and cusp points is derived as determined by the quadrupole moment of the individual images as observables. In addition, we read off the relative parities between the images, so that the parity of all images is determined, when one is known. We compare all retrievable ratios of potential derivatives to the actual ones and to those obtained by using the quadrupole moment as observable for two and three image configurations generated by a galaxy-cluster scale singular isothermal ellipse. We conclude that using the quadrupole moments as observables, the properties of the critical curve at the cusp points are retrieved to higher accuracy, at the fold points to lower accuracy, and the ratios of second order potential derivatives to comparable accuracy. We show that the approach using ratios of convergences and reduced shear is equivalent to ours close to the critical curve but yields more accurate results and is more robust because it does not require a special coordinate system like the approach using potential derivatives. T is determined by mapping manually assigned reference points in the images onto each other. If the assignment of reference points is subject to measurement uncertainties under noise, we find that the confidence intervals of the lens parameters can be as large as the values, when the uncertainties are larger than one pixel. Observed multiple images with resolved features are more extended than unresolved ones, so that higher order moments should be taken into account to improve the reconstruction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑