Aqua MODIS Band 24串扰条纹

Aqua MODIS Band 24 Crosstalk Striping

Graziela R. Keller, Zhipeng Wang, Aisheng Wu, Xiaoxiong Xiong

摘要:

与Terra航天器上的前身不同,Aqua MODIS一直被认为不会受到电子串扰对其图像的严重有害影响。然而,最近的努力引起了我们的注意,在Aqua中分辨率成像光谱仪24波段(4.47 $μ$ m)的图像中存在条纹状伪影,经进一步检查证明,这对L1 B产品的质量有明显的影响,并且自2002年任务开始以来一直存在。使用来自预定的月球观测的月球图像,我们将伪影与波段24的探测器1的响应的电子串扰污染联系起来,该电子串扰污染由从波段26(1.375 $μ$ m)的探测器10发送的信号引起,波段26是同一焦平面组件中的相邻波段。在本文中,我们报告了这些发现、我们采取的伪影缓解策略以及我们在恢复波段24探测器1行为和图像质量方面的成功。

英文摘要:

Aqua MODIS, unlike its predecessor on board the Terra spacecraft, had always been thought to have been spared from significant deleterious impacts of electronic crosstalk on its imagery. However, recent efforts brought to our attention the presence of striping artifacts in Aqua MODIS images from band 24 (4.47$μ$m), which upon further inspection proved to have a noticeable impact on the quality of the L1B product and to have been present since the beginning of the mission, in 2002. Using images of the Moon from scheduled lunar observations, we linked the artifacts with electronic crosstalk contamination of the response of detector 1 of band 24 by signal sent from the detector 10 of band 26 (1.375$μ$m), a neighboring band in the same focal plane assembly. In this paper, we report on these findings, the artifact mitigation strategy adopted by us, and on our success in restoring band 24 detector 1 behavior and image quality.