POLARBEAR望远镜上连续旋转半波片的性能

Performance of a continuously rotating half-wave plate on the POLARBEAR telescope

Satoru Takakura, Mario Aguilar, Yoshiki Akiba, Kam Arnold, Carlo Baccigalupi, Darcy Barron, Shawn Beckman, David Boettger, Julian Borrill, Scott Chapman, Yuji C… 展开作者

Satoru Takakura, Mario Aguilar, Yoshiki Akiba, Kam Arnold, Carlo Baccigalupi, Darcy Barron, Shawn Beckman, David Boettger, Julian Borrill, Scott Chapman, Yuji Chinone, Ari Cukierman, Anne Ducout, Tucker Elleflot, Josquin Errard, Giulio Fabbian, Takuro Fujino, Nicholas Galitzki, Neil Goeckner-Wald, Nils W. Halverson, Masaya Hasegawa, Kaori Hattori, Masashi Hazumi, Charles Hill, Logan Howe, Yuki Inoue, Andrew H. Jaffe, Oliver Jeong, Daisuke Kaneko, Nobuhiko Katayama, Brian Keating, Reijo Keskitalo, Theodore Kisner, Nicoletta Krachmalnicoff, Akito Kusaka, Adrian T. Lee, David Leon, Lindsay Lowry, Frederick Matsuda, Tomotake Matsumura, Martin Navaroli, Haruki Nishino, Hans Paar, Julien Peloton, Davide Poletti, Giuseppe Puglisi, Christian L. Reichardt, Colin Ross, Praween Siritanasak, Aritoki Suzuki, Osamu Tajima, Sayuri Takatori, Grant Teply

摘要:

在宇宙微波背景(CMB)偏振测量中,连续旋转半波片(CRHWP)是一种提高大角度灵敏度的有效工具。利用CRHWP,单个检测器可以测量三个斯托克斯参数,即$I$、$Q$和$U$,从而避免由正交检测器对的特性中的失配引入的一组系统误差。我们专注于实现CRHWP在大口径望远镜(即主镜是大于当前的最大半波片直径的$\sim$ 0.5 m),其中CRHWP可以放置在主镜和焦平面之间。在这种配置中,需要解决光学器件的偏振强度($I{\rightarrow}P$)泄漏,其成为1/f噪声的来源,并且还引起由CMB温度波动引起的差分增益系统。在本文中,我们提出的性能CRHWP安装在北极熊实验中,它采用了格里高利望远镜与2.5米的主要照明模式。CRHWP被放置在主镜和次镜之间的主焦点附近。我们发现,$I{\rightarrow}P$泄漏大于我们的主镜的物理特性的预期,导致在100 mHz的1/f膝盖。过量泄漏可能是由于检测器系统中的缺陷,即检测器响应度和时间常数的非线性。然而,我们证明,通过减去与强度信号相关的泄漏,1/f噪声拐点频率降低到32 mHz(对于我们的扫描策略,$\ell \sim$ 39),这对于探测原始B模式信号非常有希望。我们还讨论了在未来项目中进一步减少噪声的方法,其中仪器组件的精确温度控制和泄漏减少将发挥关键作用。

英文摘要:

A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of $\sim$0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization ($I{\rightarrow}P$) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the POLARBEAR experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the $I{\rightarrow}P$ leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz ($\ell \sim$39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑