在$γ$射线能量高达2 MeV的情况下超高精度refractive index测量Si
Ultra high precision refractive index measurement of Si at $γ$-ray energies up to 2 MeV
摘要:
利用GAMS 6双晶谱仪研究了硅在$γ$射线能量为181 - 1959 keV时的折射率,发现其符合经典散射模型的预测。这与早些时候在GAMS 5光谱仪上的测量结果形成对比,该测量结果表明光子能量高于500 keV时折射率的符号变化。我们对2011年的原始数据以及2013年的数据进行了重新评估,其中我们表明棱镜衍射效应引起的系统误差可以解释早期的数据。
英文摘要:
The refractive index of silicon at $γ$-ray energies from 181 - 1959 keV was investigated using the GAMS6 double crystal spectrometer and found to follow the predictions of the classical scattering model. This is in contrast to earlier measurements on the GAMS5 spectrometer, which suggested a sign-change in the refractive index for photon energies above 500 keV. We present a re-evaluation of the original data from 2011 as well as data from a 2013 campaign in which we show that systematic errors due to diffraction effects of the prism can explain the earlier data.