在4K下进行互谱噪声测量以最小化功率分配器反相关效应
Cross-spectrum noise measurements at 4 K to minimize power-splitter anti-correlation effect
摘要:
本文报道了在300 K温度下对热限电子振荡器相位噪声的精确测量。热限制是指振荡器的白信噪比处于或接近50欧姆源电阻器的热噪声产生的水平。该方法消除了互谱技术中共模功分器的反相关效应。通过将功率分配器冷却到液氦温度(4K)来减轻反相关效应。本文中的测量结果首次证明了理论主张,即通过低温冷却可以显着降低分配器的附加热噪声,并且这可以消除使用双通道互谱技术引入的任何反相关噪声。在液氮温度为77 K的条件下,测量到的偏反相关误差为(-1.3 +/-0.6)dB,与理论值相符。
英文摘要:
We report an accurate measurement of the phase noise of a thermally limited electronic oscillator at 300 K. By thermally limited we mean that the white signal-to-noise ratio of the oscillator is at or near the level generated by the thermal noise of the 50 ohm source resistor. The measurement is devoid of the anti-correlation effect that originates from the common mode power splitter in a cross-spectrum technique. The anti-correlation effect is mitigated by cooling the power splitter to a liquid helium temperature (4 K). The measurements in this paper are the first proof of theoretical claims that additive thermal noise from the splitter can be reduced significantly with cryogenic cooling and this can eliminate any anti-correlated noise introduced by use of the two-channel cross-spectrum technique. We also confirm measurements of partial anti-correlation error of (-1.3 +/- 0.6) dB that agree with theory when the splitter is at liquid nitrogen temperature of 77 K.