使用混沌多目标优化的分数阶负荷频率控制在互联电力系统中

Fractional Order Load-Frequency Control of Interconnected Power Systems Using Chaotic Multi-objective Optimization

Indian Institute of Technology Delhi(印度德里理工学院);Jadavpur University(贾达普大学);University of Southampton(南安普顿大学)

Indranil Pan, Saptarshi Das

AI总结:

本文研究了使用混沌多目标优化设计分数阶PI控制器以提高互联电力系统的负荷频率控制性能,通过比较不同优化算法的解质量和计算时间,验证了FOPID控制器在处理冲突时间域设计目标方面的优势。

摘要:

分数阶比例-积分-微分(FOPID)控制器被设计用于两个互联电力系统的负荷频率控制(LFC)。在基于多目标优化(MOO)的设计框架中,考虑了冲突的时间域设计目标,以设计FOPID控制器的增益和分数阶微分积分阶次。本文探讨了在流行的MOO算法非支配排序遗传算法-II(NSGA-II)中加入两种不同的混沌映射以及均匀随机数生成器(RNG)的影响。采用不同的MOO质量度量标准,如超体积指标、基于动量惯量的多样性度量、总帕累托展开、间距度量,以从所有NSGA-II变体(即标准和混沌版本)的多次运行中选择最佳的控制器参数集。将混沌版本的NSGA-II算法与标准NSGA-II在解质量和计算时间方面进行比较。此外,比较帕累托最优前沿,以显示在两个冲突的时间域设计目标之间权衡的优劣,从而展示FOPID控制器相较于简单PID控制器的优势。还探讨了FOPID结构的快速/慢速和高/低噪声放大效应,或电力系统两个互联区域的四象限操作性质。接下来采用基于模糊逻辑的方法,从每个MOO比较标准对应的最佳帕累托前沿中选择最佳折中解。在标准运行条件下,展示模糊最佳折中解的时间域系统响应。然后报告每种控制器结构的优缺点比较分析。还对PID和FOPID控制器进行了鲁棒性分析。

英文摘要:

Fractional order proportional-integral-derivative (FOPID) controllers are designed for load frequency control (LFC) of two interconnected power systems. Conflicting time domain design objectives are considered in a multi objective optimization (MOO) based design framework to design the gains and the fractional differ-integral orders of the FOPID controllers in the two areas. Here, we explore the effect of augmenting two different chaotic maps along with the uniform random number generator (RNG) in the popular MOO algorithm - the Non-dominated Sorting Genetic Algorithm-II (NSGA-II). Different measures of quality for MOO e.g. hypervolume indicator, moment of inertia based diversity metric, total Pareto spread, spacing metric are adopted to select the best set of controller parameters from multiple runs of all the NSGA-II variants (i.e. nominal and chaotic versions). The chaotic versions of the NSGA-II algorithm are compared with the standard NSGA-II in terms of solution quality and computational time. In addition, the Pareto optimal fronts showing the trade-off between the two conflicting time domain design objectives are compared to show the advantage of using the FOPID controller over that with simple PID controller. The nature of fast/slow and high/low noise amplification effects of the FOPID structure or the four quadrant operation in the two inter-connected areas of the power system is also explored. A fuzzy logic based method has been adopted next to select the best compromise solution from the best Pareto fronts corresponding to each MOO comparison criteria. The time domain system responses are shown for the fuzzy best compromise solutions under nominal operating conditions. Comparative analysis on the merits and de-merits of each controller structure is reported then. A robustness analysis is also done for the PID and the FOPID controllers.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑