arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1610.09246physics.ins-detphysics.med-ph
收藏

应用核医学感兴趣的多种放射性核素进行$β^-$放射引导手术的可行性

Feasibility of the $β^-$ Radio-Guided Surgery with a Variety of Radio-Nuclides of Interest to Nuclear Medicine

Carlo Mancini-Terracciano, Raffaella Donnarumma, Gaia Bencivenga, Valerio Bocci, Antonella Cartoni, Francesco Collamati, Ilaria Fratoddi, Alessandro Giordano, L… 展开作者

Carlo Mancini-Terracciano, Raffaella Donnarumma, Gaia Bencivenga, Valerio Bocci, Antonella Cartoni, Francesco Collamati, Ilaria Fratoddi, Alessandro Giordano, Luca Indovina, Michela Marafini, Silvio Morganti, Dante Rotili, Andrea Russomando, Teresa Scotognella, Elena Solfaroli Camillocci, Marco Toppi, Giacomo Traini, Iole Venditti, Riccardo Faccini

摘要:

在健康组织背景相关的情况下,基于$β^-$的放射引导手术克服了相应的$γ$技术。它只能在标记有$^{90}$ Y的放射性示踪剂可用的情况下使用,因为当前探头原型针对该放射性核素的发射光谱进行了优化。在这里,我们研究,与一组实验室测试和模拟,原型能力的情况下,不同的放射性核素是在核医学中使用的选择。因此,我们估计作为能量的函数的电子和光子的探测效率,我们评估的可行性,利用选定的放射性核素的无线电引导手术。我们的结论是,在使用$^{31}$ Si、$^{32}$ P、$^{97}$ Zr和$^{188}$ Re的情况下,当前的探针原型需要在1~s内通过施用3~MBq/Kg的放射性同位素来检测0.1~ml的残留物,才能在SUV和TNR的大范围值内产生显著的信号。相反,需要调节检测器以有效使用$^{83}$ Br、$^{133}$ I和$^{153}$ Sm,尽管它们已经可以在高SUV或TNR值的情况下使用。最后,$^{18}$ F、$^{67}$ Cu、$^{131}$ I和$^{177}$ Lu不能用于当前探头设计的无线电引导手术。

英文摘要:

The $β^-$ based radio-guided surgery overcomes the corresponding $γ$ technique in case the background from healthy tissues is relevant. It can be used only in case a radio-tracer marked with $^{90}$Y is available since the current probe prototype was optimized for the emission spectrum of this radio-nuclide. Here we study, with a set of laboratory tests and simulations, the prototype capability in case a different radio-nuclide is chosen among those used in nuclear medicine. As a result we estimate the probe efficiency on electrons and photons as a function of energy and we evaluate the feasibility of a radio-guided surgery exploiting the selected radio-nuclides. We conclude that requiring a 0.1~ml residue to be detected within 1~s by administering 3~MBq/Kg of radio-isotope, the current probe prototype would yield a significant signal in a vast range of values of SUV and TNR in case $^{31}$Si,$^{32}$P, $^{97}$Zr, and $^{188}$Re are used. Conversely, a tuning of the detector would be needed to efficiency use $^{83}$Br, $^{133}$I, and $^{153}$Sm, although they could already be used in case of high SUV or TNR values. Finally, $^{18}$F,$^{67}$Cu, $^{131}$I, and $^{177}$Lu are not useable for radio-guided surgery with the current probe design.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑