arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1610.07255gr-qcphysics.optics
收藏

用于提高引力波探测器灵敏度带宽的光机械谐振器中1064 nm负色散介质

Negative dispersion medium at 1064 nm in an optomechanical resonator for enhancing the sensitivity bandwidth in a gravitational-wave detector

Minchuan Zhou, Selim M. Shahriar

摘要:

最近,我们提出了一种光泵五能级增益EIT(GEIT)系统,该系统具有叠加在增益分布上的透明度下降,并表现出适合于白光腔(WLC)增强干涉引力波探测器的负色散[Phys.Rev.D.2003]。92,082002(2015)]。在WLC-SR(信号再循环)方案中使用该系统作为负色散介质(NDM),我们得到了量子噪声(QN)限制的灵敏度带宽积的约18倍的增强。我们还展示了如何在实践中使用$^{87}$ Rb中795 nm处的塞曼子能级来实现这样的系统[Opt. Commun. 402,382-388(2017)]。然而,aLIGO在1064 nm处工作,并且在此波长处不可获得Rb或其他碱金属原子中的合适跃迁。因此,有必要考虑与aLIGO的工作波长一致的系统。在这里,我们提出了实现这样的NDM在1064 nm的微谐振器,它支持光机械相互作用。在较高频率下施加强控制场,并且在某些条件下,较低频率下的探测场在吸收分布的中心处经历峰值,并且在透射中经历负色散。与GEIT的情况下,我们使用的复合腔信号回收(CC-SR)计划,其中一个辅助镜插入在暗端口的检测器,并表明,增强因子可以高达~15。然而,使用灵敏度增强所需的参数,光机系统进入控制场耗尽的不稳定区域。我们提出了一个基于观测器的反馈控制过程,用于稳定CC-SR系统。

英文摘要:

Recently, we had proposed an optically-pumped five-level Gain EIT (GEIT) system, which has a transparency dip superimposed on a gain profile and exhibits a negative dispersion suitable for the white light cavity (WLC) enhanced interferometric gravitational wave detector [Phys. Rev. D. 92, 082002 (2015)]. Using this system as the negative dispersion medium (NDM) in the WLC-SR (signal recycling) scheme, we get an enhancement in the quantum noise (QN) limited sensitivity-bandwidth product by a factor of ~18. We have also shown how to realize such a system in practice using Zeeman sublevels in $^{87}$Rb at 795nm [Opt. Commun. 402, 382-388 (2017)]. However, aLIGO operates at 1064nm and suitable transitions in Rb or other alkali atoms are not available at this wavelength. Therefore, it is necessary to consider a system that is consistent with the operating wavelength of aLIGO. Here, we present the realization of such an NDM at 1064nm with a microresonator, which supports optomechanical interaction. A strong control field is applied at a higher frequency, and, under certain conditions, a probe field at a lower frequency experiences a peak at the center of an absorption profile, and a negative dispersion in the transmission. Unlike in the GEIT case, we use the compound-cavity signal-recycling (CC-SR) scheme, where an auxiliary mirror is inserted in the dark port of the detector, and show that the enhancement factor can be as high as ~15. However, using the parameters required for the sensitivity enhancement, the optomechanical system enters an instability region where the control field is depleted. We present an observer based feedback control process used to stabilize the CC-SR system.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑