窗式空调机组需求响应控制模型及控制成本的实验确定
Experimental Determination of Demand Response Control Models and Cost of Control for Ensembles of Window-Mount Air Conditioners
摘要:
用于提供电网服务的消费者电气设备的控制在参与控制的负载的范围和多样性方面都在扩展,但是很少有适合于控制设计和用于评估控制成本的这些设备的基于实验的模型。一个实验室规模的测试系统的开发,实验评估使用一个简单的窗口安装空调电网调节服务。实验测试台是嵌入在测试系统中的单个隔离空调,该测试系统既模拟空调房间的热力学,又将空调与真实世界的外部环境和人为变量隔离,这些变量干扰捕获完全表征控制响应函数和控制成本的模型所需的仔细测量。控制响应函数和控制成本使用温度设定点的谐波扰动和进一步将空调与低频环境变化隔离的测试协议来测量。
英文摘要:
Control of consumer electrical devices for providing electrical grid services is expanding in both the scope and the diversity of loads that are engaged in control, but there are few experimentally-based models of these devices suitable for control designs and for assessing the cost of control. A laboratory-scale test system is developed to experimentally evaluate the use of a simple window-mount air conditioner for electrical grid regulation services. The experimental test bed is a single, isolated air conditioner embedded in a test system that both emulates the thermodynamics of an air conditioned room and also isolates the air conditioner from the real-world external environmental and human variables that perturb the careful measurements required to capture a model that fully characterizes both the control response functions and the cost of control. The control response functions and cost of control are measured using harmonic perturbation of the temperature set point and a test protocol that further isolates the air conditioner from low frequency environmental variability.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。