arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1610.00186physics.med-ph
收藏

具有动态光束衰减器的光子计数光谱CT

Photon counting spectroscopic CT with dynamic beam attenuator

Haluk Atak, Polad M. Shikhaliev

摘要:

目的:光子计数(PC)计算机断层成像(CT)可以在最低患者剂量下提供材料选择性CT成像,但是其遭受次优计数率。动态射束衰减器(DBA)可以通过调制X射线束强度来帮助计数率,使得患者的低衰减区域接收较低的曝光,并且这些区域后面的探测器不会过度曝光。然而,DBA可能会硬化光束并导致伪影和错误。本研究探讨了在PCCT中使用DBA的积极和消极影响。研究方法:使用120 kVp管电压和14 mGy空气剂量模拟和研究了具有单个能量箱的简单PCCT、具有2个和5个能量箱的光谱PCCT以及具有和不具有DBA的常规能量积分CT。DBA由软组织(ST)等效材料、铁(Fe)和钬(Ho)K形边缘材料制成。使用圆柱形CT体模和含碘和CaCO 3造影剂的胸部体模。确定了一般和材料分解CT的图像伪影和量化误差。结果:当使用DBA时,简单PCCT表现出主要的图像伪影和定量误差。2bin光谱PCCT减少了伪影和误差,5 bin光谱CT几乎消除了伪影和误差。由于较低能量光子的强吸收,Fe-DBA确实存在光子饥饿噪声。使用ST-DBA和Ho-DBA的5箱PCCT几乎没有伪影和光子饥饿噪声。Ho-DBA更好地保存了低能光子,减少了射束硬化伪影,并改善了材料分解。此外,Ho-DBA也是微型的,具有1.4mm的厚度和2cm的长度,比Fe-DBA小得多。结论:由K边缘材料(例如Ho)制造的DBA可以解决PCCT的计数率问题,并且以最低的患者剂量提供微型尺寸、最小的图像伪影和改进的材料分解。

英文摘要:

Purpose: Photon counting (PC) computed tomography (CT) can provide material selective CT imaging at lowest patient dose but it suffers from suboptimal count rate. A dynamic beam attenuator (DBA) can help with count rate by modulating x-ray beam intensity such that the low attenuating areas of the patient receive lower exposure, and detector behind these areas is not overexposed. However, DBA may harden the beam and cause artifacts and errors. This work investigates positive and negative effects of using DBA in PCCT. Methods: A simple PCCT with single energy bin, spectroscopic PCCT with 2 and 5 energy bins, and conventional energy integrating CT with and without DBA were simulated and investigated using 120kVp tube voltage and 14mGy air dose. The DBAs were modeled as made from soft tissue (ST) equivalent material, iron (Fe), and holmium (Ho) K-edge material. A cylindrical CT phantom and chest phantom with iodine and CaCO3 contrast elements were used. Image artifacts and quantification errors in general and material decomposed CT were determined. Results: Simple PCCT exhibited major image artifacts and quantification errors when DBAs were used. The artifacts and errors were decreased with 2bin spectroscopic PCCT and nearly eliminated with 5bin spectroscopic CT. The photon starvation noise did present with Fe-DBA due to strong absorption of lower energy photons. The 5bin PCCT with ST-DBA and Ho-DBA were nearly free of artifacts and photon starvation noise. The Ho-DBA better preserved low energy photons and decreased beam hardening artifacts, and improved material decomposition. Also, the Ho-DBA was also miniature having 1.4mm thickness and 2cm length, much smaller than Fe-DBA. Conclusion: DBA fabricated from K-edge material such as Ho can address count rate problem of PCCT and provide miniature size, minimal image artifacts, and improved material decomposition at lowest patient dose.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑