arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1608.07069physics.ins-detphysics.bio-ph
收藏

金刚石绝缘石墨通道微电极阵列实时检测嗜铬细胞和肾上腺切片的胞吐事件

Microelectrode arrays of diamond-insulated graphitic channels for real time detection of exocytotic events from cultured chromaffin cells and slices of adrenal glands

F. Picollo, A. Battiato, E. Bernardi, A. Marcantoni, A. Pasquarelli, E. Carbone, P. Olivero, V. Carabelli

摘要:

将微结构化石墨4x 4多电极阵列嵌入单晶金刚石基底(4x 4(μ G-SCD MEA))中,用于实时监测来自培养的嗜铬细胞和肾上腺切片的胞吐事件。目前的方法依赖于平行离子束光刻技术的发展,这确保了具有可再现电极尺寸的扩展阵列的时间有效的制造。报道的装置适用于进行高灵敏度和时间分辨率的安培和伏安记录,通过同时采集由200 μ m间隙隔开的16个矩形微电极(20 × 3.5 μ m^2)的数据。利用阵列几何形状,我们解决了以下具体问题:i)同时检测直接培养在装置表面上的几个嗜铬细胞的自发和KCl诱发的分泌,ii)解析胞吐事件的不同子集的波形,iii)监测肾上腺薄片的量子分泌事件。自发释放的频率较低(肾上腺片和培养细胞分别为0.12 Hz和0.3 Hz),并在培养细胞中用30 mM KCl刺激后增加至0.9 Hz。尖峰振幅以及上升和衰减时间与碳纤维微电极测量的那些相当,并且允许识别与“完全融合”事件、“吻和跑”和“吻和留”胞吐相关的分泌事件的三个不同子集,确认该装置具有用于实时记录的足够的灵敏度和时间分辨率。该设备提供了显著的优势,通过允许同时记录原代细胞培养物或完整组织中的细胞群来缩短收集数据的时间。

英文摘要:

A microstructured graphitic 4x4 multielectrode array was embedded in a single crystal diamond substrate (4x4 {uG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time effective fabrication of extended arrays with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20x3.5 um^2) separated by 200 um gaps. Taking advantage of the array geometry we addressed the following specific issues: i) detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, ii) resolve the waveform of different subsets of exocytotic events, iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 Hz and 0.3 Hz respectively for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated to "full fusion" events, "kiss and-run" and "kiss-and-stay" exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑