arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1607.06885cond-mat.soft
收藏

有限塑性形变时的体积守恒

Volume conservation during finite plastic deformation

He-Ling Wang, Dong-Jie Jiang, Li-Yuan Zhang, Bin Liu

摘要:

一个弹塑性理论如果不恰当地将任意塑性应变率张量设为偏量,就不是体积守恒的。本文讨论了在有限应变状态下,特别是在弹塑性理论中不采用卸载应力自由位形或卸载应力自由位形不唯一的情况下,如何严格实现体积守恒。本文阐明并应用了体积守恒的一个精确条件,即在完全去除外加载荷后,体积元的密度应与初始无应力状态下的密度相等。对于采用卸载应力自由位形(即中间位形)的弹塑性理论,只有在塑性应变率的定义中加入了许多不同的定义,才能满足精确的体积守恒条件。对于不采用卸载无应力位形的弹塑性理论,由于缺乏无应力状态的信息,实现体积守恒就更加困难。为了寻找一种无论是否采用卸载应力自由位形都能实现弹塑性理论体积守恒的普遍途径,我们提出了材料密度只取决于Cauchy应力迹的单一假设,有趣的是发现塑性应力率的零迹等价于体积守恒的精确条件。进一步提出了两种策略来满足体积守恒的精确条件:直接和轻微地修改切线刚度张量或使用适当选择的应力/应变测量和弹性柔度张量。将它们应用到现有的弹塑性理论中,并通过理论证明和数值算例证明了其体积守恒性。

英文摘要:

An elastoplastic theory is not volume conserved if it improperly sets an arbitrary plastic strain rate tensor to be deviatoric. This paper discusses how to rigorously realize volume conservation in finite strain regime, especially when the unloading stress free configuration is not adopted or unique in the elastoplastic theories. An accurate condition of volume conservation is clarified and used in this paper that the density of a volume element after the applied loads are completely removed should be identical to that of the initial stress free states. For the elastoplastic theories that adopt the unloading stress free configuration (i.e. the intermediate configuration), the accurate condition of volume conservation is satisfied only if specific definitions of the plastic strain rate are used among many other different definitions. For the elastoplastic theories that do not adopt the unloading stress free configuration, it is even more difficult to realize volume conservation as the information of the stress free state lacks. To find a universal approach of realizing volume conservation for elastoplastic theories whether or not adopt the unloading stress free configuration, we propose a single assumption that the density of material only depends on the trace of the Cauchy stress, and interestingly find that the zero trace of the plastic stress rate is equivalent to the accurate condition of volume conservation. Two strategies are further proposed to satisfy the accurate condition of volume conservation: directly and slightly revising the tangential stiffness tensor or using a properly chosen stress/strain measure and elastic compliance tensor. They are implemented into existing elastoplastic theories, and the volume conservation is demonstrated by both theoretical proof and numerical examples.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑