人类连接体计划中扫描长度和收缩对静息状态功能连接可靠性的影响
Effects of Scan Length and Shrinkage on Reliability of Resting-State Functional Connectivity in the Human Connectome Project
摘要:
在本文中,我们使用人类连接组项目(N=461)的数据,研究扫描长度对静息状态功能磁共振成像(rsfMRI)产生的静息状态功能连接(rsFC)估计的可靠性的影响。此外,我们还研究了经验贝叶斯收缩的好处,其中主题级估计通过交易偏差的小幅增加来更大程度地减少方差,从而从总体平均值中借用力量。对于每一个主题,我们计算原始和收缩rsFC之间的估计300个区域,通过独立成分分析(ICA)的基础上rsfMRI扫描不同的长度从3到30分钟。使用二元回归确定每个区域的时间过程,并将rsFC估计为每对时间过程之间的皮尔逊相关性。将每例受试者的收缩估计值计算为原始受试者水平估计值和总体平均估计值之间的加权平均值,其中通过受试者内方差与受试者间方差的关系确定每个连接的权重。我们发现,对于大多数连接,收缩估计比原始估计具有更高的可靠性,使用长度小于10分钟的扫描时,收缩估计的可靠性提高了30-40%,使用20-30分钟的扫描时,收缩估计的可靠性提高了10-20%。我们还观察到原始和收缩估计的可靠性存在显着的空间变异性,默认模式和运动网络内的连接表现出最大的可靠性,网络间的连接表现出最差的可靠性。我们的结论是,可靠估计rsFC所需的扫描长度取决于感兴趣的特定连接,收缩可以用来提高可靠性的rsFC,即使是从长,高质量的rsfMRI扫描。
英文摘要:
In this paper, we use data from the Human Connectome Project (N=461) to investigate the effect of scan length on reliability of resting-state functional connectivity (rsFC) estimates produced from resting-state functional magnetic resonance imaging (rsfMRI). Additionally, we study the benefits of empirical Bayes shrinkage, in which subject-level estimates borrow strength from the population average by trading a small increase in bias for a greater reduction in variance. For each subject, we compute raw and shrinkage estimates of rsFC between 300 regions identified through independent components analysis (ICA) based on rsfMRI scans varying from 3 to 30 minutes in length. The time course for each region is determined using dual regression, and rsFC is estimated as the Pearson correlation between each pair of time courses. Shrinkage estimates for each subject are computed as a weighted average between the raw subject-level estimate and the population average estimate, where the weight is determined for each connection by the relationship of within-subject variance to between-subject variance. We find that shrinkage estimates exhibit greater reliability than raw estimates for most connections, with 30-40% improvement using scans less than 10 minutes in length and 10-20% improvement using scans of 20-30 minutes. We also observe significant spatial variability in reliability of both raw and shrinkage estimates, with connections within the default mode and motor networks exhibiting the greatest reliability and between-network connections exhibiting the poorest reliability. We conclude that the scan length required for reliable estimation of rsFC depends on the specific connections of interest, and shrinkage can be used to increase reliability of rsFC, even when produced from long, high-quality rsfMRI scans.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。