arXiv 1606.05640astro-ph.IM
收藏

基于模型的JWST机载NIRSpec空间和光谱定标方法

A model-based approach to the spatial and spectral calibration of NIRSpec onboard JWST

Bernhard Dorner, Giovanna Giardino, Pierre Ferruit, Catarina Alves de Oliveira, Stephan M. Birkmann, Torsten Böker, Guido De Marchi, Xavier Gnata, Jess Köhler, … 展开作者

Bernhard Dorner, Giovanna Giardino, Pierre Ferruit, Catarina Alves de Oliveira, Stephan M. Birkmann, Torsten Böker, Guido De Marchi, Xavier Gnata, Jess Köhler, Marco Sirianni, Peter Jakobsen

摘要:

内容:詹姆斯·韦伯太空望远镜(JWST)的NIRSpec仪器可以在多目标(MOS)、长缝和积分场(IFU)模式下工作,光谱分辨率从100到2700。它的MOS模式使用大约25万个可单独寻址的微型狭缝进行对象选择,覆盖了$\sim$ 9 $\mathrm{arcmin}^2$的视场。目的:用于从NIRSpec探测器图像中提取波长校准光谱的管道在很大程度上依赖于NIRSpec光学几何模型。我们演示了如何从一个小子集的NIRSpec模式和孔径的专用校准数据可以用来优化这个参数模型的必要水平的保真度。研究方法:在迭代过程之后,手动调整模型参数的初始基准值,然后自动优化,使得模型预测的来自固定狭缝、IFU和MOS孔径的小子集的图像和谱线的位置与它们在仪器的主光学平面中的测量位置相匹配。结果:NIRSpec参数模型能够高保真地再现输入光谱的空间和光谱位置。从所提取的校准光谱测量的模型的固有精度(1-sigma,RMS)优于沿空间方向的像素的1/10,并且对于所有基于光栅的光谱模式,优于在光谱方向上的分辨率元素的1/20。这与NIRSpec空间和光谱校准预算中的相应分配完全一致。

英文摘要:

Context: The NIRSpec instrument for the James Webb Space Telescope (JWST) can be operated in multiobject (MOS), long-slit, and integral field (IFU) mode with spectral resolutions from 100 to 2700. Its MOS mode uses about a quarter of a million individually addressable minislits for object selection, covering a field of view of $\sim$9 $\mathrm{arcmin}^2$. Aims: The pipeline used to extract wavelength-calibrated spectra from NIRSpec detector images relies heavily on a model of NIRSpec optical geometry. We demonstrate how dedicated calibration data from a small subset of NIRSpec modes and apertures can be used to optimize this parametric model to the necessary levels of fidelity. Methods: Following an iterative procedure, the initial fiducial values of the model parameters are manually adjusted and then automatically optimized, so that the model predicted location of the images and spectral lines from the fixed slits, the IFU, and a small subset of the MOS apertures matches their measured location in the main optical planes of the instrument. Results: The NIRSpec parametric model is able to reproduce the spatial and spectral position of the input spectra with high fidelity. The intrinsic accuracy (1-sigma, RMS) of the model, as measured from the extracted calibration spectra, is better than 1/10 of a pixel along the spatial direction and better than 1/20 of a resolution element in the spectral direction for all of the grating-based spectral modes. This is fully consistent with the corresponding allocation in the spatial and spectral calibration budgets of NIRSpec.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑