用垂直Halbach八极永磁体阵列超冷中子阱测量中子寿命和有效的谱净化
Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array
摘要:
超冷中子(UCN)存储测量是在一个陷阱中进行的,该陷阱由1.3 T Halbach Octupole PEr(HOPE)磁体阵列垂直排列而成,使用劳厄-朗之万研究所PF 2源的TES端口。在捕集器底部的机械UCN阀用于填充和排空。该阀用Fomblin润滑脂覆盖,以诱导非镜面反射,并与从顶部插入的可移动聚乙烯UCN去除器结合使用,用于清洁阈值以上的UCN。由于UCN去极化的损失被抑制与最小2 mT的偏置场。在不使用UCN去除剂的情况下,观察到$(712 \pm 19)$ s的总储存时间常数;在去除剂插入80 s并在距离捕集器底部80 cm或65 cm处使用的情况下,观察到$(824 \pm 32)$ s和$(835 \pm 36)$ s的时间常数。结合后两个值,在对UCN阀处的损失进行初步校正后,提取出$τ_{\rm n} = (887 \pm 39)$ s的中子寿命。在清洁过程中的UCN人口的时间常数进行了观察和比较的UCN动力学理论的基础上,以及Monte-Carlo研究的计算。这些计算用于预测在无去除器、80 cm去除器和65 cm去除器测量中清洁后剩余的$\sim 5\%$、$\sim 0.5\%$和$\sim 10^{-12}\%$的阈值以上群体。因此,通过使用覆盖整个陷阱底部的非镜面反射器和陷阱顶部的去除器,我们已经建立了一个有效的清洁程序,用于去除磁性存储UCN的高精度$τ_{\rm n}$实验中的主要系统效应。
英文摘要:
Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $τ_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $τ_{\rm n}$ experiments with magnetically stored UCNs.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。