arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1605.09554physics.comp-phphysics.flu-dyn
收藏

Potential of enhancing a natural convection loop with a thermomagnetically pumped ferrofluid

Eskil Aursand, Magnus Aa. Gjennestad, Karl Yngve Lervåg, Halvor Lund

英文摘要:

The feasibility of using a thermomagnetically pumped ferrofluid to enhance the performance of a natural convection cooling loop is investigated. First, a simplified analytical estimate for the thermomagnetic pumping action is derived, and then design rules for optimal solenoid and ferrofluid are presented. The design rules are used to set up a medium-scale (1 m, 10-1000 W) case study, which is modeled using a previously published and validated model (Aursand et al. [1]). The results show that the thermomagnetic driving force is significant compared to the natural convection driving force, and may in some cases greatly surpass it. The results also indicate that cooling performance can be increased by factors up to 4 and 2 in the single-phase and two- phase regimes, respectively, even when taking into the account the added heat from the solenoid. The performance increases can alternatively be used to obtain a reduction in heat-sink size by up to 75 %.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑