arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1605.06684eess.SYcs.SY
收藏

利用被动滤波器抑制工业电力系统的谐波

Harmonics Mitigation of Industrial Power System Using Passive Filters

Mehran University of Engineering & Technology(梅赫拉工程与技术大学)

Zubair Ahmed Memon, Mohammad Aslam Uquaili, Mukhtiar Ali Unar

AI总结:

本文提出设计两种被动滤波器以减少工业电力系统中非线性负载产生的谐波电流,通过Matlab/Simulink仿真验证了滤波器对谐波的抑制效果及功率因数的提升。

摘要:

随着现代工业技术的发展,电力系统中非线性负载数量增加,导致电力系统产生谐波畸变。同时,电能质量和安全运行状况下降。因此,在这种情况下,谐波抑制显得尤为必要。本文提出了两种被动滤波器的设计,以减少工业电力系统中非线性负载产生的谐波电流。Matlab/Simulink软件已用于仿真目的。通过有无安装滤波器的仿真结果,观察到安装滤波器后,电流谐波减少,功率因数提高。

英文摘要:

With the development of modern industrial technology a large number of non-linear loads are used in power system, which causes harmonic distortion in the power system. At the same time the power quality and safe operation becomes inferior. Therefore mitigation of harmonics is very necessary under the situation. This paper presents the design of two passive filters to reduce the current harmonics produced by nonlinear loads in industrial power system. Matlab /simulink software has been used for the simulation purpose. The results have been obtained with and without installation of filters and then it is observed that after installation of filters harmonics of the current are reduced and power factor is improved.