arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1604.05764math.NAcs.NAq-bio.NC
收藏

一种混合有限元方法用于求解脑电图前向问题

A Mixed Finite Element Method to Solve the EEG Forward Problem

University of Münster(明斯特大学);Scientific Computing and Imaging (SCI) Institute, University of Utah(犹他大学科学计算与成像研究所);Institute for Applied Mathematics, University of Münster(明斯特大学应用数学研究所);Cluster of Excellence EXC 1003, Cells in Motion, CiM, Münster(明斯特市卓越集群“细胞运动”(EXC 1003));Tampere University of Technology(坦佩雷理工大学);Aalto University(阿尔托大学);Institute for Biomagnetism and Biosignalanalysis, University of Münster(明斯特大学生物磁学与生物信号分析研究所)

Johannes Vorwerk, Christian Engwer, Sampsa Pursiainen, Carsten H. Wolters

AI总结:

本文提出一种基于混合有限元方法的新型方法,用于求解脑电图前向问题,该方法通过引入电流作为额外未知数,实现电流守恒,从而在特定场景下提高模拟精度。

摘要:

有限元方法已被证明在数值求解脑电图前向问题时能实现高精度,并能够对复杂几何形状和重要导电特征如各向异性导电性进行现实建模。到目前为止,大多数现有方法都依赖于连续伽辽金(CG)-FEM相同的底层公式。在本文中,提出了一种基于混合有限元方法(混合-FEM)的新方法用于求解脑电图前向问题。为了获得混合-FEM公式,电流被引入为除电势外的额外未知数。作为这一推导的结果,混合-FEM通过构造是电流守恒的,与CG-FEM不同。因此,在某些情况下可以实现更高的模拟精度,例如当薄绝缘结构如颅骨的直径在网格分辨率范围内时。本文给出了混合-FEM方法用于脑电图前向模拟的理论推导,并描述了用于求解所产生方程组的算法。随后,展示了在球体和真实头部模型中的首次评估,并将结果与之前引入的CG-FEM方法进行比较。此外,还展示了额外的可视化以说明混合-FEM的电流守恒特性。基于这些结果,得出结论,新提出的混合-FEM至少可以补充,并在某些情况下甚至优于已建立的CG-FEM方法,这促使进一步评估混合-FEM在生物电磁学中的应用。

英文摘要:

Finite element methods have been shown to achieve high accuracies in numerically solving the EEG forward problem and they enable the realistic modeling of complex geometries and important conductive features such as anisotropic conductivities. To date, most of the presented approaches rely on the same underlying formulation, the continuous Galerkin (CG)-FEM. In this article, a novel approach to solve the EEG forward problem based on a mixed finite element method (Mixed-FEM) is introduced. To obtain the Mixed-FEM formulation, the electric current is introduced as an additional unknown besides the electric potential. As a consequence of this derivation, the Mixed-FEM is, by construction, current preserving, in contrast to the CG-FEM. Consequently, a higher simulation accuracy can be achieved in certain scenarios, e.g., when the diameter of thin insulating structures, such as the skull, is in the range of the mesh resolution. A theoretical derivation of the Mixed-FEM approach for EEG forward simulations is presented, and the algorithms implemented for solving the resulting equation systems are described. Subsequently, first evaluations in both sphere and realistic head models are presented, and the results are compared to previously introduced CG-FEM approaches. Additional visualizations are shown to illustrate the current preserving property of the Mixed-FEM. Based on these results, it is concluded that the newly presented Mixed-FEM can at least complement and in some scenarios even outperform the established CG-FEM approaches, which motivates a further evaluation of the Mixed-FEM for applications in bioelectromagnetism.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑