基于相电流测量的风力发电机故障检测:置换熵方法
On wind Turbine failure detection from measurements of phase currents: a permutation entropy approach
摘要:
本文提出了基于排列熵的时间序列复杂性测度在风力发电机组故障检测中的适用性。一组电气数据从一个故障和一个健康的风力涡轮机进行了分析,使用传统的快速傅立叶分析,除了置换熵分析,比较两个涡轮机的相电流随时间的复杂性指数。4秒长的数据集没有显示电流频谱中的任何低频,也没有显示两个涡轮机电流之间的频谱有任何有意义的差异。两台汽轮机同相电流波形的排列熵分析发现,随着时间的推移,有不同的复杂度值,其中一个明显高于其他。Yan et.在他的研究中发现,较高的熵值与旋转机器中故障的存在有关。在这条轨道之后,将进一步努力将我们的研究中发现的熵差与其中一个风能转换系统中可能存在的故障联系起来。
英文摘要:
This article presents the applicability of Permutation Entropy based complexity measure of a time series for detection of fault in wind turbines. A set of electrical data from one faulty and one healthy wind turbine were analysed using traditional FastFourier analysis in addition to Permutation Entropy analysis to compare the complexity index of phase currents of the two turbines over time. The 4 seconds length data set did not reveal any low frequency in the spectra of currents, neither did they show any meaningful differences of spectrum between the two turbine currents. Permutation Entropy analysis of the current waveforms of same phases for the two turbines are found to have different complexity values over time, one of them being clearly higher than the other. The work of Yan et. al. in has found that higher entropy values related to thepresence of failure in rotary machines in his study. Following this track, further efforts will be put into relating the entropy difference found in our study to possible presence of failure in one of the wind energy conversion systems.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。