arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1508.03885physics.ins-detcond-mat.mtrl-sci
收藏

无GHz Laser时间分辨透射电子显微术:频闪高占空比方法

GHz Laser-free Time-resolved Transmission Electron Microscopy: a Stroboscopic High-duty-cycle Method

Jiaqi Qiu, Gwanghui Ha, Chunguang Jing, Sergey V. Baryshev, Bryan W. Reed, Yimei Zhu, June W. Lau

摘要:

提供了一种用于通过脉冲输入直流(dc)电子束来产生具有GHz重复率的超短电子脉冲的设备和方法。该装置和方法基于由一系列横向偏转腔和磁四极子组成的电磁-机械脉冲发生器(EMMP)。EMMP调制和斩波输入的直流电子束,并将其转换为皮秒和亚皮秒(100 fs至10 ps)电子脉冲序列,重复频率>1 GHz。将电磁多路复用器应用于具有任意直流电子源的透射电子显微镜,可以实现GHz频闪高占空比透射电子显微镜。与时间分辨TEM的许多最新发展不同,这些发展依赖于样品泵浦激光器与从光电阴极发射电子的激光器配对来探测样品,在所提出的实验装置中没有激光器。这对于不熟悉激光系统的电子显微镜工作者来说是一个很大的安慰。EMMP和样品由通过延迟线同步的射频(RF)源外部驱动。在没有激光泵浦样品的情况下,消除了激光诱导的残余加热/损坏样品的问题。由于许多RF驱动的过程可以无限循环,因此可以实现1-50 GHz的采样率。这样的GHz频闪TEM将开辟一个新的范例,在原位和在operando实验研究样品外部驱动的电磁。作为对激光光阴极TEM实现的较低(MHz)重复率实验的补充,所提出的RF设计将实现高重复率多GHz范围内的新实验。在这篇文章中,我们报告的EMMP和分析广义矩阵方法在薄透镜近似的优化设计,以及详细的光束动力学,实际现实的直流束参数在TEM工作在200千电子伏。

英文摘要:

A device and a method for producing ultrashort electron pulses with GHz repetition rates via pulsing an input direct current (dc) electron beam are provided. The device and the method are based on an electromagnetic-mechanical pulser (EMMP) that consists of a series of transverse deflecting cavities and magnetic quadrupoles. The EMMP modulates and chops the incoming dc electron beam and converts it into pico- and sub-pico-second (100 fs to 10 ps) electron pulse sequences at >1 GHz repetition rates. Applying the EMMP to a transmission electron microscope (TEM) with any dc electron source, a GHz stroboscopic high-duty-cycle TEM can be realized. Unlike in many recent developments in time-resolved TEM that rely on a sample pumping laser paired with a laser launching electrons from a photocathode to probe the sample, there is no laser in the presented experimental set-up. This is expected to be a significant relief for electron microscopists who are not familiar with laser systems. The EMMP and the sample are externally driven by a radiofrequency (RF) source synchronized through a delay line. With no laser pumping the sample, the problem of the laser induced residual heating/damaging the sample is eliminated. As many RF-driven processes can be cycled indefinitely, sampling rates of 1-50 GHz become accessible. Such a GHz stroboscopic TEM would open up a new paradigm for in situ and in operando experiments to study samples externally driven electromagnetically. Complementary to the lower (MHz) repetition rates experiments enabled by laser photocathode TEM, new experiments in the high rep-rate multi-GHz regime will be enabled by the proposed RF design. In this article, we report an optimal design of the EMMP and an analytical generalized matrix approach in the thin lens approximation, along with detailed beam dynamics taking actual realistic dc beam parameters in a TEM operating at 200 keV.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑